Suche
Aktueller Filter
• Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
• 4.3351.10.000 • Frequency output (1082 Hz at 50 m/s) • Supply 3.3 ... 42 V DC • W/o heating
• 4.3351.00.000 • Frequency output (1082 Hz at 50 m/s) • Supply 3.3 ... 42 V DC • Heated
• 4.3351.00.140 • Frequency output (1082 Hz at 50 m/s) • Analogue output (0 ... 20 mA = 0.3...75 m/s) • Supply 15 ... 24 V DC • Heated
• 4.3351.10.140 • Frequency output (1082 Hz at 50 m/s) • Analogue output (0 ... 20 mA = 0.3...75 m/s) • Supply 15 ... 24 V DC • W/o heating
• 4.3351.00.141 • Frequency output (1082 Hz at 50 m/s) • Analogue output (4 ... 20 mA = 0.3...75 m/s) • Supply 15 ... 24 V DC • Heated
• 4.3351.10.141 • Frequency output (1082 Hz at 50 m/s) • Analogue output (4 ... 20 mA = 0.3...75 m/s) • Supply 15 ... 24 V DC • W/o heating
• 4.3351.00.161 • Frequency output (1082 Hz at 50 m/s) • Analogue output (0 ... 10 V = 0.3...75 m/s) • Supply 15 ... 24 V DC • Heated
• 4.3351.10.161 • Frequency output (1082 Hz at 50 m/s) • Analogue output (0 ... 10 V = 0.3...75 m/s) • Supply 15 ... 24 V DC • W/o heating
• 4.3520.00.000 • Measurement Range: 0.5...50 m/s • Accuracy: ± 0.5 m/s or 3% of measuremet value • Resolution: 0.1 m/s • Frequency output (2 - 573 Hz) • Supply 15 ... 28 V DC • With heating • Opto-electronic principle
• Fits to Thies First Class sensors (anemometer and wind vanes) • Galvanic separation of sensor from boom & met mast structure • Druable POM thermoplastic • UV resistant
• 4.3520.10.000 • Measurement Range: 0.5...50 m/s • Accuracy: ± 0.5 m/s or 3% of measuremet value • Resolution: 0.1 m/s • Frequency output (2 - 573 Hz) • Supply 15 ... 28 V DC • W/o heating • Opto-electronic principle
• Fits to Thies Compact sensors (anemometer and wind vanes) • Galvanic separation of sensor from boom & met mast structure • Druable POM thermoplastic • UV resistant
• Fits to WindSensor anemometer P2546A-OPR and P2546C-OPR • Galvanic separation of sensor from boom & met mast structure • Druable POM thermoplastic • UV resistant
• A100R/K • Switching anemometer (reed switch) • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100LM • Low power pulse output (10 Hz per m/s) • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100LK • Low power pulse output (10 Hz per knot) • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100L2 • Low power pulse frequency • Analogue Voltage output • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100AC • Low power • Low level AC output (1.55 Hz per m/s) • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• Fits to all Vector Instruments sensors (anemometers, wind vanes and several others) that use a type 405 or 405/27P mounting adaptor • Galvanic separation of sensor from boom & met mast structure • Druable POM thermoplastic • UV resistant
Service includes: • Inspection • Inspection report • For all anemometer types and models • Subsequent to inspection, Client decides if a sensor shall undergo Certified Maintenance & Refurbishment Service or, if needed, repair
For Thies First Class Anemometers: • Maintenance and Inspection • Authorised refurbishment • Exchange of bearings, O-rings, sealings • Certificate • Authorisation seal • Inspection report
For all anemometer types and models: • Repair (sensor specific) • Maintenance and inspection • Refurbishment • Certificate Scope & costs for repair depend on the individual sensor defects & conditions. A sensor specific offer will be made based upon inspection.
{{.}}
{{{.}}}