Skip to Content

Sensors & Measurement Equipment

WindSensor Anemometer, calibrated - P2546C OPR

• Calibrated according to IEC and MEASNET standard
• First Class in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Measurement Range: <0.4...75 m/s
• Self-excited , no external power supply required)
850.00 €

WindSensor Anemometer, calibrated - P2546A OPR

• Calibrated according to IEC and MEASNET standard
• First Class in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Measurement Range: <0.4...75 m/s
• Self-excited (pull-up resistor of 10…100 kΩ required)
850.00 €

NRG Anemometer, MEASNET calibrated - NRG 40C

• Output Signal: 0 Hz to 125 Hz
• Measurement Range: 1 ... 96 m/s
• Supply voltage: None needed
390.00 €

NRG Anemometer, MEASNET calibrated - NRG S1

• Frequency output: 0 Hz to 800 Hz
• Supply 5 ... 28 VDC
• Measurement Range: 0.6...75 m/s
• Resolution: 0.046 m/s
• Operating temperature range: -50 °C … 80 °C
• W/o heating
680.00 €

Surge and Discharge Isolator - Protection for Thies Ultrasonic Anemometer

• Fits Thies ultrasonic anemometers
• Galvanic separation of sensor from boom & met mast structure
• Durable POM thermoplastic
• UV resistant
30.00 €

Thies Device to Refuse Birds for Ultrasonic Anemometer - 507245

• 507245
• Consisting of 1x wire and 2x clip
• Suitable for Thies Ultrasonic Anemometer 1D and 2D
19.80 €

Thies Bird Spike for Ultrasonic Anemometer - 508396

• one spike and protective cap
20.00 €

Thies 3D Ultrasonic Anemometer, fully heated - 4.3830.42.300

• PTC Heating Stainless-steel caps and additional chassis heating
• Measurement variables possible (3 dimensions):
• Horizontal and vertical components of wind speed
• Wind direction
• Virtual temperature
• Wind measurement range: [0.01 ... 85 m/s]
• Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90°
• Virtual temperature measurement range: - 40°C ... +70°C
• Sample rate: 0.1 Hz ... 100 Hz
• Half Duplex Interface Configuration with Baud rate of 38400/N81
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics and heating of 48V AC/DC
• Maintenance free
5,079.50 €

Thies 3D Ultrasonic Anemometer - 4.3830.20.340

• Measurement variables possible (3 dimensions):
• Horizontal and vertical components of wind speed
• Wind direction
• Virtual temperature
• Wind measurement range: [0.01 ... 85 m/s]
• Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90°
• Virtual temperature measurement range: - 40°C ... +70°C
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Maintenance free
• Digital /analogue in- and outputs
4,224.50 €

Thies 2D Ultrasonic Anemometer, fully heated - 4.3820.42.300

• PTC Heating Stainless-steel caps and additional chassis heating
• Measurement variables possible (2 dimensions):
• Horizontal components of wind speed
• Wind direction
• Virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360° (0...540°, 0...720° analogue adjustable)
• Virtual temperature measurement range: - 50°C ... +70°C
• Half Duplex Interface Configuration with Baud rate of 38400/N81  
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics and heating of 48V AC/DC
• Maintenance free
3,648.00 €

Thies 2D Ultrasonic Anemometer - 4.3820.32.300

• Measurement variables possible (2 dimensions):
• Horizontal components of wind speed
• Wind direction
• Virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360° (0...540°, 0...720° analogue adjustable)
• Virtual temperature measurement range: - 50°C ... +70°C
• Half Duplex Interface Configuration with Baud rate of 38400/N81  
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Maintenance free
2,816.00 €

Thies 2D Ultrasonic Anemometer - 4.3820.00.000

• Measurement variables possible (2 dimensions):
• Horizontal components of wind speed
• Wind direction
• Virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360° (0...540°, 0...720° analogue adjustable)
• Virtual temperature measurement range: - 50°C ... +70°C
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Maintenance free
• Digital /analogue in- and outputs

Northring Adapter for Thies Ultrasonic Anemometer

• Adapter is aligned to north by means of a bearing tube
• A pin in the adapter and a north boring in the base of the anemometer guarantee that the sensor is aligned to north
• No realignment necessary with replacement of the sensor
• Fixing boring for mast and sensor of 50mm diameter
• Aluminum
65.00 €

Thies 2D Ultrasonic Anemometer, compact - 4.3877.27.000

• Standard Heating Stainless-steel caps 
• With optionally integrated Baro-transmitter  • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360°
• Virtual temperature measurement range: - 50°C ... +70°C
• Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2)
• Output range: 10 per 1 sec  
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics and heating of 12 VDC
• Maintenance free
3,364.50 €

Thies 2D Ultrasonic Anemometer, compact - 4.3877.07.000

• Standard Heating Stainless-steel caps  • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360°
• Virtual temperature measurement range: - 50°C ... +70°C
• Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2)
• Output range: 10 per 1 sec  
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics and heating of 12 VDC
• Maintenance free
3,272.50 €

Thies 2D Ultrasonic Anemometer, compact - 4.3875.60.340

• Reinforced heating with 48 VDC • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360°
• Virtual temperature measurement range: - 50°C ... +70°C
• Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2)
• Output range: 10 per 1 sec  
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics of 12 VDC
• Maintenance free
2,172.50 €

Thies 2D Ultrasonic Anemometer, compact - 4.3875.20.381

• Standard Heating Stainless-steel caps 
• With optionally integrated Baro-transmitter  • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360°
• Virtual temperature measurement range: - 50°C ... +70°C
• Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2)
• Output range: 10 per 1 sec  
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics and heating of 12 VDC
• Maintenance free
2,230.00 €

Thies 2D Ultrasonic Anemometer, compact - 4.3875.20.340

• Standard Heating Stainless-steel caps 
• With optionally integrated Baro-transmitter  • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360°
• Virtual temperature measurement range: - 50°C ... +70°C
• Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2)
• Output range: 10 per 1 sec  
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics and heating of 12 VDC
• Maintenance free
2,230.00 €

Thies 2D Ultrasonic Anemometer, compact - 4.3875.00.340

• Standard Heating Stainless-steel caps
• Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360°
• Virtual temperature measurement range: - 50°C ... +70°C
• Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2)
• Output range: 10 per 1 sec  
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics and heating of 12 VDC
• Maintenance free
2,110.00 €

Thies 2D Ultrasonic Anemometer, compact - 4.3875.00.260

• Standard Heating Stainless-steel caps
• Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360°
• Virtual temperature measurement range: - 50°C ... +70°C
• Full Duplex Interface Configuration with Baud rate of 4800/N81 and NMEA Telegram  
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics and heating of 12 VDC
• Maintenance free
2,110.00 €