Thies First Class Advanced II Anemometer, unheated - 4.3352.10.000

• Frequency output (1082 Hz at 50 m/s)
• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• Supply 3.3 ... 48 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
703.00 €

Thies 3D Ultrasonic Anemometer - 4.3830.22.503

• Measurement variables possible (3 dimensions):
• Horizontal and vertical components of wind speed
• Wind direction
• Virtual temperature
• Wind measurement range: [0.01 ... 85 m/s]
• Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90°
• Virtual temperature measurement range: - 40°C ... +70°C
• Sample rate: 0.1 Hz ... 100 Hz
• Half Duplex Interface Configuration with Baud rate of 38400/N81
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Maintenance free
4,101.00 €

R. M. Young Gill Propeller Anemometer - 27106T

• Carbon Fibre Thermoplastic Propeller (CFT): 08254
• Range: 0-40 m/s (90 mph) 
• Transducer: DC generator (single direction)
• Self-powered
742.00 €

Vector Instruments -Windspeed Ltd.- Anemometer - A100LK

• Low power pulse output (10 Hz per knot)
• First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
650.00 €

Thies First Class Advanced X Anemometer, unheated - 4.3352.10.400

• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• W/o heating
• Measurement Range: 0.3...75 m/s
• Outputs: RS485 / ASCII / MODBUS
• Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
• Measures next to wind speed also:    Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)    Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)    Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)    Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
864.00 €

WindSensor Anemometer, calibrated - P2546D OPR

• Calibrated according to IEC and MEASNET standard
• First Class in accordance to IEC 61400-12-1
• Measurement Range: <0.3...75 m/s
• Resolution: 0.001 m/s @ 10-minute average mode
• Self-excited (pull-up resistor of 10…100 kΩ required)
825.00 €

R.M. Young Wind Monitor HD Alpine, rugged ice-resistant anemometer - 05108-45

• 05108-45
• Combines Heavy Duty unit version along with the ice-resistant coating
• Wind speed measurement range: 0 ... 100 m/s
• Wind direction measurement range: azimuth: 0 ... 360° mechanical
• Signal output (wind speed): magnetically induced AC voltage
• Signal output (wind direction): analog DC voltage (10 kΩ)
• Operating temperature range: -50°C to 60°C
• Power requirement (potentiometer excitation): 15 VDC max.
1,939.00 €

Thies First Class Advanced II Anemometer, heated - 4.3352.00.000

• Frequency output (1082 Hz at 50 m/s)
• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• With heating (24V AC/DC, 25W)
• Supply 3.3 ... 48 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
742.00 €

Thies First Class Advanced X Anemometer, heated - 4.3352.00.400

• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• With heating (24V AC/DC, 25W)
• Measurement Range: 0.3...75 m/s
• Outputs: RS485 / ASCII / MODBUS • Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
• Measures next to wind speed also:    Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)    Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)    Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)    Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
922.00 €

Thies First Class Advanced I Anemometer, unheated - 4.3351.10.000

• Frequency output (1082 Hz at 50 m/s)
• Class A compliance in accordance to IEC 61400-50-1 (latest version)
• Supply 3.3 ... 42 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
• W/o heating
703.00 €

Thies First Class Advanced I Anemometer, heated - 4.3351.00.000

• Frequency output (1082 Hz at 50 m/s)
• Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Supply 3.3 ... 42 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
• With heating (24V AC/DC, 25W)
742.00 €

Thies First Class Advanced X Anemometer, unheated - 4.3352.10.401

• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• W/o heating
• Measurement Range: 0.3...75 m/s
• Outputs: RS485 / ASCII / MODBUS
• Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
• Measures next to wind speed also:    Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)    Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)    Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)    Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
864.00 €

Thies First Class Advanced X Anemometer, heated - 4.3352.00.401

• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• With heating (24V AC/DC, 25W)
• Measurement Range: 0.3...75 m/s
• Outputs: RS485 / ASCII / MODBUS
• Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
• Measures next to wind speed also:    Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)    Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)    Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)    Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
922.00 €

Thies First Class Advanced I Anemometer, unheated - 4.3351.10.161

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (0 ... 10 V = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• W/o heating
742.00 €

Thies First Class Advanced I Anemometer, heated - 4.3351.00.161

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (0 ... 10 V = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• Heated
765.00 €

Thies First Class Advanced I Anemometer, unheated - 4.3351.10.140

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (0 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• W/o heating
742.00 €

Thies First Class Advanced I Anemometer, heated - 4.3351.00.140

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (0 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• Heated
765.00 €

Thies First Class Advanced I Anemometer, unheated - 4.3351.10.141

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (4 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• W/o heating
742.00 €

Thies First Class Advanced I Anemometer, heated - 4.3351.00.141

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (4 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• Heated
765.00 €

Thies First Class Advanced II Anemometer, refurbished, calibrated, 1yr warranty

• Frequency output (1082 Hz at 50 m/s)
• Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Supply 3.3 ... 42 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
• With heating (24V AC/DC, 25W)