Skip to Content

Thies First Class Anemometer

Thies First Class Advanced II Anemometer, unheated - 4.3352.10.000

• Frequency output (1082 Hz at 50 m/s)
• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• Supply 3.3 ... 48 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
703.00 €

Thies First Class Advanced X Anemometer, unheated - 4.3352.10.400

• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• W/o heating
• Measurement Range: 0.3...75 m/s
• Outputs: RS485 / ASCII / MODBUS
• Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
• Measures next to wind speed also:    Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)    Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)    Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)    Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
864.00 €

Thies First Class Advanced II Anemometer, heated - 4.3352.00.000

• Frequency output (1082 Hz at 50 m/s)
• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• With heating (24V AC/DC, 25W)
• Supply 3.3 ... 48 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
742.00 €

Thies First Class Advanced X Anemometer, heated - 4.3352.00.400

• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• With heating (24V AC/DC, 25W)
• Measurement Range: 0.3...75 m/s
• Outputs: RS485 / ASCII / MODBUS • Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
• Measures next to wind speed also:    Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)    Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)    Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)    Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
922.00 €

Thies First Class Advanced I Anemometer, unheated - 4.3351.10.000

• Frequency output (1082 Hz at 50 m/s)
• Class A compliance in accordance to IEC 61400-50-1 (latest version)
• Supply 3.3 ... 42 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
• W/o heating
703.00 €

Thies First Class Advanced I Anemometer, heated - 4.3351.00.000

• Frequency output (1082 Hz at 50 m/s)
• Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Supply 3.3 ... 42 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
• With heating (24V AC/DC, 25W)
742.00 €

Thies First Class Advanced X Anemometer, unheated - 4.3352.10.401

• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• W/o heating
• Measurement Range: 0.3...75 m/s
• Outputs: RS485 / ASCII / MODBUS
• Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
• Measures next to wind speed also:    Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)    Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)    Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)    Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
864.00 €

Thies First Class Advanced X Anemometer, heated - 4.3352.00.401

• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• With heating (24V AC/DC, 25W)
• Measurement Range: 0.3...75 m/s
• Outputs: RS485 / ASCII / MODBUS
• Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
• Measures next to wind speed also:    Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)    Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)    Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)    Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
922.00 €

Thies First Class Advanced I Anemometer, unheated - 4.3351.10.161

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (0 ... 10 V = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• W/o heating
742.00 €

Thies First Class Advanced I Anemometer, heated - 4.3351.00.161

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (0 ... 10 V = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• Heated
765.00 €

Thies First Class Advanced I Anemometer, unheated - 4.3351.10.140

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (0 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• W/o heating
742.00 €

Thies First Class Advanced I Anemometer, heated - 4.3351.00.140

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (0 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• Heated
765.00 €

Thies First Class Advanced I Anemometer, unheated - 4.3351.10.141

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (4 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• W/o heating
742.00 €

Thies First Class Advanced I Anemometer, heated - 4.3351.00.141

• Frequency output (1082 Hz at 50 m/s)
• Analogue output (4 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC 
• Heated
765.00 €

Thies First Class Advanced II Anemometer, refurbished, calibrated, 1yr warranty

• Frequency output (1082 Hz at 50 m/s)
• Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Supply 3.3 ... 42 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
• With heating (24V AC/DC, 25W)
350.00 €

Thies First Class Advanced I Anemometer, refurbished, calibrated, 1yr warranty

• Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Supply 3.3 ... 42 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or <0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
350.00 €

Surge and Discharge Isolator - Protection for Thies First Class Sensors

• Fits to Thies First Class sensors (anemometer and wind vanes)
• Galvanic separation of sensor from boom & met mast structure
• Durable POM thermoplastic
• UV resistant
20.00 €

Thies Styrofoam Protected Packing Box -OEM- for Anemometer

For all Thies First Class sensors anemometer and wind vanes
• OEM recommended in order to maintain warranty