Skip to Content

Campbell Accessories

Campbell Scientific Monitoring Platform - MeteoPV

• Purpose-built photovoltaic resource data platform
• Integrated surge and ESD protection
• SCADA ready

Campbell Scientific general-purpose, multiplexed analog measurement module - VOLT 116

• General-purpose, multiplexed analog measurement module
• 16 differential or 32 single-ended input channels with 2 excitation channels
• 2x switched 12V and 4x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific general-purpose, multiplexed analog measurement module - VOLT 108

• General-purpose, multiplexed analog measurement module
• 8 differential or 16 single-ended input channels with 2 excitation channels
• 1x switched 12V and 2x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific 20-Channel Thermocouple Module - TEMP 120

• Purpose-built thermocouple measurement module
• Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers 
• 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors
• Resolution of 0.015°C
• Handles extreme temperature environments and rapid thermal gradients
• Time base can be referenced either to GPS or a temperature-compensated real-time clock
• CPI DAQ connection for channel expansion
• USB 2.0 interface for PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific 4-Channel Serial Input/Output Module - SDM-SIO4A

• Compatible with CR1000X and other models

Campbell Scientific 16-Channel Input/Output Module - SDM-IO16A

• Compatible with CR1000X and other models
• Connects to the data logger via three ports that can be shared with up to 15 other SDM devices
• Adds 16 digital I/O ports
• Operating Temperature: -40°C to 70°C

Campbell Scientific USB Storge Extension & Portable Configurator - SC115

• USB (2.0) interface with up to 2GB flash storage
• Allows Plug&Play field upgrades and configuration by using our Device Configuration utility
• Expands data logger storage by 2 GB, tandem operation with Compact Flash card possible
• Shuttles data, OS, and program files between Campbell Scientific dataloggers and a PC
• For CR800, CR850, CR1000, CR6, CR3000, CR5000, CR9000(X)

Campbell Scientific Wireless Networl Link Interface - NL241

• Connects directly to the peripheral port

Campbell Scientific Network Link Interface - NL201

• Connects directly to the peripheral port

Campbell Scientific Ethernet and CF Card Module - NL116

• Ethernet Interface
• Allows communications over local networks via TCP/IP
• Compact Flash Module• Expands data logger storage via CompactFlash® by up to 2 GB
• For CR1000 and CR3000
• Connects directly to the peripheral port

Campbell Scientific Low Level AC Pulse Counter Interface - LLAC4

• Compatible with CR1000X and other models

Campbell Scientific Measurement and Control Data Acquisition System - GRANITE 9

• One of the most computationally powerful data-acquisition devices from Campbell Scientific
• 24 bit and 32 bit ADC
• An all-digital measurement and control DAQ
• 8x digital I/O terminals (configurable) 
• 2x switched 12V 
• EPI port switch for high-speed connection to all GRANITE modules
• Built-in GPS for network synchronization
• Built-in Wi-Fi
• 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB
• Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific Measurement and Control Data Acquisition System - GRANITE 6

• An all-digital measurement and control DAQ
• 24-bit ADC
• 12x individually configured inputs for analog or digital functions
• 16x terminals configurable for digital I/O
• Built-in Wi-Fi and USB Micro-B for computer connectivity
• 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific Measurement and Control Data Acquisition System - GRANITE 10

• One of the most computationally powerful data-acquisition devices from Campbell Scientific
• 24 bit and 32 bit ADC
• An all-digital measurement and control DAQ
• 8x digital I/O terminals (configurable) 
• 4 General-purpose CAN channels
• 2x switched 12V 
• EPI port switch for high-speed connection to all GRANITE modules
• Built-in GPS for network synchronization
• Built-in Wi-Fi
• 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB
• Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific 100-Ohm Current Terminal Input Module - CURS100

• Enables a Campbell Scientific data logger to measure a sensor with current output signal, e.g. 4-20 mA; converts the current signal to voltage signal  

Campbell Scientific Portable Keyboard and Display Screen - CR1000KD

• 8 lines x 21 characters with 16-character keyboard
• Powered by the data logger power supply
• Allows to check the datalogger's status, display or plot sensor readings and stored values, and enter numeric data or change port/flag state
• Supports custom menus
• Can be easily carried from station to station in a datalogger network

Campbell Scientific Compact Flash Module - CFM100

• Compact Flash Module
• For CR1000 and CR3000
• Expands data logger storage via CompactFlash® by up to 2 GB
• Connects directly to the peripheral port

Campbell Scientific 4G LTE Cat1 Cellular Module - CELL215

• Connects directly to the peripheral port

Campbell Scientific Static Keyboard & Display - CD100

• Compatible with PV1000X
• Allows to check Datalogger status, change ports, enter numeric data and view or plot sensor data
• Operating temperature: -45°C to 85°C   

Campbell Scientific 2-Channel Vibrating Wire Analyzer Module - AVW 200

• AVW 200 interfaces 2-channel vibrating wire sensors
• 3 digital control ports (C1 – C3)
• Measurement Resolution 0.001 Hz RMS
• ±250 mV differential input range; -55° to +85°C