Skip to Content

Solar Power Sensors

Hukx Pyranometer Ball-leveling - BL01

• Ball levelling for SR05

Hukx Dual Pyranometer Mounting Fixture - TLM01

• For all Hukseflux pyranometer models 
• For mounting at round tube
• For horizontal and tilted pyranometer levelling and mounting

Hukx Digital Thermopile Pyranometer, calibrated - SR30-M2-D1

• ISO 9060: Secondary Standard
• Measurement range: -400 W/m² to 4000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet (traceable to WRR)
• For Global Horizontal Irradiance (GHI) measurements (W/m2) 
• Sunshine duration (optional)

Hukx Pyranometer, calibrated - SR300-D1

• ISO 9060: Secondary Standard
• Heating, tilt sensor, internal ventilation
• No external ventilator required and mitigates dew and frost
• Measurement range: -400 to 4000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet (traceable to WRR)
• Power consumption (dew and frost mitigation mode): < 3 W

Hukx Thermopile Pyranometer, calibrated - SR20-T2

• ISO 9060: Secondary Standard
• Measurement range: 0 W/m² to 4000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet (traceable to WRR)
• For Global Horizontal Irradiance (GHI) measurements (W/m2) 
• Sunshine duration (optional)
• With 10 kOhm thermistor
• With heating

Hukx Thermopile Pyranometer, calibrated - SR20-T1

• ISO 9060: Secondary Standard
• Measurement range: 0 W/m² to 4000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet (traceable to WRR)
• For Global Horizontal Irradiance (GHI) measurements (W/m2) 
• Sunshine duration (optional)
• With Pt100
• With heating

Hukx Digital Thermopile Pyranometer, calibrated - SR20-D2

• Most accurate digital secondary standard pyranometer available
• ISO 9060: Secondary Standard
• Measurement range: -400 W/m² to 4000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet (traceable to WRR)
• For Global Horizontal Irradiance (GHI) measurements (W/m2) 
• Sunshine duration (optional)

Hukx Pyranometer, calibrated - SR200-D1

• ISO 9060: Secondary Standard
• Measurement range: -400 to 4000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet (traceable to WRR)
• Power consumption (low power mode): < 0.5 W

Hukx Pyranometer, calibrated - SR15-D2A2

• ISO 9060: Class B
• Measurement range: 0 to 3000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet with each sensor; traceable to World Radiometric Reference (WRR)
• Communication:    Analog: 4-20 mA    Digital: Modbus RS-485
• Power Consumption: < 0.048 W at 12 VDC (unheated)

Hukx Pyranometer, calibrated - SR15-D1

• ISO 9060: Class B
• Measurement range: 0 to 3000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet with each sensor; traceable to World Radiometric Reference (WRR)
• Communication: Modbus RS-485
• Power Consumption: < 0.048 W at 12 VDC (unheated)

Hukx Thermopile Pyranometer, calibrated - SR15

• ISO 9060: First Class
• Measurement range: 0 W/m² to 3000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet
• For Global Horizontal Irradiance (GHI) measurements (W/m2) 
• Self-powered

Hukx Thermopile Pyranometer, calibrated - SR11

• ISO 9060: First Class
• Measurement range: 0 W/m² to 3000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet
• For Global Horizontal Irradiance (GHI) measurements (W/m2) 
• Self-powered

Hukx Pyranometer, calibrated - SR05-D2A2

• ISO 9060: Class C
• Measurement range: 0 to 2000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet with each sensor; traceable to World Radiometric Reference (WRR)
• Response time: 18 s
• Communication:    Analog: 4 to 20 mA    Digital: Modbus RS-485

Hukx Pyranometer, calibrated - SR05-D1A3

• ISO 9060: Class C
• Measurement range: 0 to 2000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet with each sensor; traceable to World Radiometric Reference (WRR)
• Response time: 18 s
• Communication:    Analog: 0 to 1 V    Digital: Modbus RS-485

Hukx Pyranometer, calibrated - SR05-A1

• ISO 9060: Class C
• Measurement range: 0 to 2000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet with each sensor; traceable to World Radiometric Reference (WRR)
• Response time: 18 s
• Communication: Analog mV

Hukx Dual Pyranometer Mounting Fixture - PMF02

• For all Hukseflux pyranometers: 1x horizontal and 1x tilted pyranometer

Hukx Pyranometer Mounting Fixture - PMF01

• For all Hukseflux pyranometers: 1 x pyranometer, horizontal or tilted

Hukx Thermopile Pyranometer, calibrated - LP02

• ISO 9060 ‘Second Class’ compliant
• Measurement range: 0 W/m² to 2000 W/m²
• Spectral range: 305 nm to 2800 nm
• Incl. calibration sheet
• For Global Horizontal Irradiance (GHI) measurements (W/m2) 
• Self-powered

Kipp & Zonen Sun Tracker - RaZON+

• Output: RS-485 Modbus/ASCII and Ethernet RJ-45
• Input power supply: 20 to 30 VDC;
• Measurement range: PR1/PH1 0 to 1500 W/m²
• Pointing accuracy: 0.2°
• Sample rate: 1Hz
11,600.00 €

Kipp & Zonen Pyranometer, calibrated - SP Lite2

 Measuring range: 0 to 2,000 W/m²
• Sensitivity: 60 to 100 μV/W/m²
• Spectral range: 400 to 1,100 nm
• Output signal: 0 to 20 mV; 4 to 20 mA (with extra module)
• Operating temperature: -30°C to +70°C
• Self-powered
• IP 67
395.00 €