Skip to Content

All products

Thies First Class Advanced II Anemometer, unheated - 4.3352.10.000

• Frequency output (1082 Hz at 50 m/s)
• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• Supply 3.3 ... 48 V DC
• Measurement Range: 0.3...75 m/s
• Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s)
• Linearity: r>0.99999 (4...20 m/s)
703.00 €

Thies First Class Wind Vane, TMR, unheated - 4.3151.10.001

• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Digital output protocoll: 16 bit serial synchronous
• Digital output: 10 bit Gray Code
• Without north gap 
• Accuracy: 0.75°
• Resolution: 0.35°
• W/o heating
1,008.50 €

Thies 3D Ultrasonic Anemometer - 4.3830.22.503

• Measurement variables possible (3 dimensions):
• Horizontal and vertical components of wind speed
• Wind direction
• Virtual temperature
• Wind measurement range: [0.01 ... 85 m/s]
• Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90°
• Virtual temperature measurement range: - 40°C ... +70°C
• Sample rate: 0.1 Hz ... 100 Hz
• Half Duplex Interface Configuration with Baud rate of 38400/N81
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Maintenance free
4,101.00 €

R. M. Young Gill Propeller Anemometer - 27106T

• Carbon Fibre Thermoplastic Propeller (CFT): 08254
• Range: 0-40 m/s (90 mph) 
• Transducer: DC generator (single direction)
• Self-powered
742.00 €

Vector Instruments -Windspeed Ltd.- Anemometer - A100LK

• Low power pulse output (10 Hz per knot)
• First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
650.00 €

Thies First Class Advanced X Anemometer, unheated - 4.3352.10.400

• Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2
• W/o heating
• Measurement Range: 0.3...75 m/s
• Outputs: RS485 / ASCII / MODBUS
• Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain)
• Measures next to wind speed also:    Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C)    Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °)    Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz)    Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
864.00 €

WindSensor Anemometer, calibrated - P2546D OPR

• Calibrated according to IEC and MEASNET standard
• First Class in accordance to IEC 61400-12-1
• Measurement Range: <0.3...75 m/s
• Resolution: 0.001 m/s @ 10-minute average mode
• Self-excited (pull-up resistor of 10…100 kΩ required)
825.00 €

Thies Compact Wind Vane, TMR, unheated - 4.3129.70.773

• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°  
• Dead band: without north gap
• Measurement principle: magnetic
• Output: 0 to 5 V
• Resolution: 0.4°
• Accuracy: ±2°
• W/o heating
• Power Supply: 8 ... 30 V DC or 24 V AC
505.50 €

Vector Instruments -Windspeed Ltd.- Wind vane - W200P

• Potentiometer 0 … 1 kOhm ±10% = 0 … 360 degrees 
• Measurement range: 1.15°...358.85°
• Dead band: 2.3° ±1.5º (continuity; north gap) / 3.5° ±1.5º (variation; dead band)
• Accuracy: ± 3° in steady winds >5m/s (±2° obtainable following calibration)
• Resolution: ± 0.2°
• Survival speed: 75m/s (150Knots, 170mph)
• Temperature range: -50 to +70°C
890.00 €

R.M. Young Wind Monitor HD Alpine, rugged ice-resistant anemometer - 05108-45

• 05108-45
• Combines Heavy Duty unit version along with the ice-resistant coating
• Wind speed measurement range: 0 ... 100 m/s
• Wind direction measurement range: azimuth: 0 ... 360° mechanical
• Signal output (wind speed): magnetically induced AC voltage
• Signal output (wind direction): analog DC voltage (10 kΩ)
• Operating temperature range: -50°C to 60°C
• Power requirement (potentiometer excitation): 15 VDC max.
1,939.00 €

Campbell Scientific Data Logger - CR1000Xe

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 16x analogue single-ended or 8 differential Analog Inputs, 10x pulse counters, 8x digital IN/OUT (configurable), 4x analogue voltage (switched excitation mode or switched regulated voltage supply), 2x switched 12V 
• RS485/232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port, Wi-Fi (optional module)
• 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB

Kintech Data Logger - Orbit 360 Premium

• 16x frequency channels [pulse counter](10 physical + 6 extra channels with Channel Expander)
• 23x analog channels [voltage] (15 physical + 8 extra channels with Channel Expander)
• 3x RS485 Client, 1x RS485 Server
• 2G/3G/4G Modem
• External Power Supply: 5-30 VDC, Internal Backup Battery 17.000 mAh
• High capacity backup memory
• Secure GPS encrypted
• Communication with SCADA
• Sampling Rate: 1Hz
3,590.00 €

NRG 16-Channel Data Logger - SymphoniePRO® 16

• 8x pulse counters IN
• 3x analog voltage IN
• Requires external 12VDC power supply
• 3x configurable 'Flex' Channels (Analog or Counter) with optional signal conditioning modules (P-SCMs)
• Resolution: 16 bit ad
• Accuracy: 0.04 % of full scale
• LCD with 16 button keypad
2,400.00 €

Campbell Scientific Data Logger - CR6

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 12x single-ended or 6x differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN, USB, RJ-45, Micro-SD card
• 4 Mbytes SRAM memory (extendable)
• Surge protection for critical Outputs by GDT or transient voltage suppression diodes
• Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)

MeteoSense Temperature, Humidity and Pressure Sensor - HTBS-2

• Temperature:
Range: -40 ... 80 °C
Accuracy: ±0.1 °C
• Humidity:
Range: 0 ... 100% rH
Accuracy: ±1% rH
• Pressure:
Range: 400 ... 1200 hPa
Accuracy (400 ... 1100 hPa, –40 ... 85 °C): ±0.9 hPa
• Linearity Compensation: 32 points
• Interfaces: RS-485, SDI-12, USB
• IP 65
• Input Voltage: 5 ... 45 VDC
550.00 €

ProfEC Ventus Barometric Pressure Sensor, calibrated (ISO 17025) - AP65

• calibrated (ISO 17025)
• 650...1050 hPa
• Output signal: 0...5V DC 
• Supply Voltage: 8 ... 32 V
• Operating temperature: -40 ... 105°C  
340.00 €

Starlink Mini Kit

• Frequency: 2,4 GHz
• IEEE 802.11 a/ac/ax/b/g/n
• 1 x LAN port 10/100/1000 Mbps
• Average power consumption: 25–40 W
• ​​​​​​​Intended for a mobile installation

Hughes Satellite Modem Terminal, BGAN - 9502

• For IP SCADA and M2M
• GPS
• Ethernet connection (RJ45)
• USB–Type B 
• RS-232 (DB9)
• External Antenna
1,700.00 €

Teltonika Industrial Cellular Router 4G LTE - RUT241

• Two Ethernet ports and wireless interface with Hotspot functionality
• Compatible with RMS
• Input voltage range of 9-30 VDC
200.00 €

Thies Clima Sensor US NHTFB - 4.9200.00.000

• Wind speed: 0.01 ... 60 m/s
• Wind direction: 0 ... 360°
• Pressure: 500 ... 1200 hPa
• Temperature: -40 ... +80 °C
• Relative Humditiy: 0 ... 100 %RH
• Brightness: 1 lux... 150 klux
• Precipitation: Intensities 0.001 ... 999mm/h
• Heating (optional) at 24 V AC/DC
• Operating voltage: 6 ... 40 VDC or 10 ... 28 VAC
• Data output digital: RS485 / RS422 and analogue: 0 ... 10V
2,368.50 €