Skip to Content

Search results for 'ProfEC Ventus' (22)

ProfEC Ventus Barometric Pressure Sensor, calibrated (ISO 17025) - AP65

• calibrated (ISO 17025)
• 650...1050 hPa
• Output signal: 0...5V DC 
• Supply Voltage: 8 ... 32 V
• Operating temperature: -40 ... 105°C  
340.00 €

Thies First Class Wind Vane, TMR, unheated - 4.3151.10.901

• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Digital output protocoll: 16 bit serial synchronous
• Digital output: 10 bit Gray Code
• Without north gap 
• Accuracy: 0.75°
• Resolution: 0.35°
• W/o heating

Thies First Class Wind Vane, TMR, heated - 4.3151.00.901

• TMR-Sensor (Tunnel Magneto Resistance)
• Measurement range: 0...360°
• Digital output protocoll: 16 bit serial synchronous
• Digital output: 10 bit Gray Code
• Without north gap 
• Accuracy: 0.75°
• Resolution: 0.35°
• With heating (25W)

ProfEC Ventus Barometric Pressure Sensor, calibrated (ISO 17025) - AP80

• calibrated (ISO 17025)
• 800...1050 hPa
• Output signal: 0...5V DC 
• Supply Voltage: 8 ... 32 V
• Operating temperature: -40 ... 105°C  
360.00 €

ProfEC Ventus Weather and Radiation Protection Shield

• Weather housing with gland to fit certain Galltec+mela, Thies and WindSensor temperature/humidity/pressure sensors
• Including mounting clamps
220.00 €

ProfEC Ventus Weather and Radiation Protection Shield with Barometer Box

• Weather housing with gland to fit certain temperature/humidity sensors
• extra box for seperate pressure sensor
• Including mounting clamps
280.00 €

Campbell Scientific general-purpose, multiplexed analog measurement module - VOLT 116

• General-purpose, multiplexed analog measurement module
• 16 differential or 32 single-ended input channels with 2 excitation channels
• 2x switched 12V and 4x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific general-purpose, multiplexed analog measurement module - VOLT 108

• General-purpose, multiplexed analog measurement module
• 8 differential or 16 single-ended input channels with 2 excitation channels
• 1x switched 12V and 2x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific 20-Channel Thermocouple Module - TEMP 120

• Purpose-built thermocouple measurement module
• Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers 
• 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors
• Resolution of 0.015°C
• Handles extreme temperature environments and rapid thermal gradients
• Time base can be referenced either to GPS or a temperature-compensated real-time clock
• CPI DAQ connection for channel expansion
• USB 2.0 interface for PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

ProfEC Ventus Energy Box

• Methanol Fuel Cell + optinal PV Modules
• 2x M28 Methanol cartridges
• 2x AGM Batteries
• Remote monitoring  
4,500.00 €

ProfEC Ventus Gas Sensor, Type B - PV-MGA8

• Sensors: Temperatur, humidity, illuminance, dew point temperature, air pressure, CO2, PM1.0/2.5/10, TSP
• Standard gas: CO, SO2, O3, NO2, H2S, NH3, TVOC, CH2O, CH4, O2, NO, Odour
• High-precision gas: CO, SO2, O3, NO2, H2S, NH3
• Configurable parameters (optional): T/H/P + CO + PM1.0 + PM2.5 + PM10
• Addable gas types (optional):
Standard gas sensor: 5 ... 8 (optional)
High-precision gas sensor: 3 ... 4 (optional)
Standard + high-precision: 1 ... 4 (standard) + 1 ... 2 (high-precision)
• Supply 12 ... 24 V DC
• Output: RS485
• Response time: < 1s
• Operating temperature: -20 ... 60℃ @ 15 ... 80 % RH

ProfEC Ventus Gas Sensor, Type A - PV-MGA8

• Sensors: Temperatur, humidity, illuminance, dew point temperature, air pressure, CO2, PM1.0/2.5/10, TSP
• Standard gas: CO, SO2, O3, NO2, H2S, NH3, TVOC, CH2O, CH4, O2, NO, Odour
• High-precision gas: CO, SO2, O3, NO2, H2S, NH3
• Configurable parameters (optional): T/H/P + CO + PM1.0 + PM2.5 + PM10
• Addable gas types (optional):
Standard gas sensor: 1 ... 4 (optional)
High-precision gas sensor: 1 ... 2 (optional)
• Supply 12 ... 24 V DC
• Output: RS485
• Response time: < 1s
• Operating temperature: -20 ... 60℃ @ 15 ... 80 % RH

ProfEC Ventus Particle Size and Dust Concentration Sensor, Digital - PSCD-D

• High sensitivity dust sensor
• Measurable particulates: PM1/ PM2.5 / PM10
• Cost effectiveness, trouble-free installation, deployment, and maintenance
• Supply: 5VDC, 12-24 VDC
• Output: RS485
• Accuracy: ±3%FS @25℃
• Operating temperature: -20℃ to +50℃ @15-80%RH
550.00 €

ProfEC Ventus Particle Size and Dust Concentration Sensor, Analog - PSCD-A

• High sensitivity dust sensor
• Measurable particulates: PM2.5 / PM10
• Cost effectiveness, trouble-free installation, deployment, and maintenance
• Supply: 5VDC, 12-24 VDC
• Output: 4-20mA, 0-5V, 0-10V
• Accuracy: ±3%FS @25℃
• Operating temperature: -20℃ to +50℃ @15-80%RH
550.00 €

Temperature-Humidity-Pressure Calibration - DAkkS (ilac-MRA) accredited

• Calibration standards traceable to U.K.A.S and/or NIST / NVLAP accreditation service (through ilac-MRA)
• Compliant to recommendations of FGW TR6, ISO / IEC and MEASNET
• Incl. calibration certificate
• Executed by a third party accredited calibration laboratory (ISO 17025)
440.00 €

Temperature-Humidity Calibration - DAkkS (ilac-MRA) accredited

• Calibration standards traceable to U.K.A.S and/or NIST / NVLAP accreditation service (through ilac-MRA)
• Compliant to recommendations of FGW TR6, ISO / IEC and MEASNET
• Incl. calibration certificate
• Executed by a third party accredited calibration laboratory (ISO 17025)
290.00 €

Temperature Calibration - DAkkS (ilac-MRA) accredited

• Calibration standards traceable to U.K.A.S and/or NIST / NVLAP accreditation service (through ilac-MRA)
• Compliant to recommendations of FGW TR6, ISO / IEC and MEASNET
• Incl. calibration certificate 
• Executed by a third party accredited calibration laboratory (ISO 17025)
160.00 €

Leasing an Offshore LiDAR

In case of a long-term RSD measurement campaign, leasing may be an attractive option to our Clients. If an RSD is rented for more than 6 months, ProfEC Ventus offers its Client to acquire the RSD device at a remaining value, which decreases on a monthly base. The value depends on the device type, age, condition and rental fee (tariff-structure) applied before during the rental term.

Leasing a LiDAR

In case of a long-term RSD measurement campaign, leasing may be an attractive option to our Clients. If an RSD is rented for more than 6 months, ProfEC Ventus offers its Client to acquire the RSD device at a remaining value, which decreases on a monthly base. The value depends on the device type, age, condition and rental fee (tariff-structure) applied before during the rental term.