Campbell Scientific

Campbell Scientific Data Logger - CR1000Xe

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 16x analogue single-ended or 8 differential Analog Inputs, 10x pulse counters, 8x digital IN/OUT (configurable), 4x analogue voltage (switched excitation mode or switched regulated voltage supply), 2x switched 12V 
• RS485/232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port, Wi-Fi (optional module)
• 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB

Campbell Scientific Data Logger - CR6

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 12x single-ended or 6x differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN, USB, RJ-45, Micro-SD card
• 4 Mbytes SRAM memory (extendable)
• Surge protection for critical Outputs by GDT or transient voltage suppression diodes
• Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)

Campbell Scientific Data Logger - CR850

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT
• RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available
• 2/4 Mbytes SRAM memory (optionally extendable) ​
• Keypad and LCD Display

Campbell Scientific Data Logger - CR800

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT
• RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available
• 2/4 Mbytes SRAM memory (optionally extendable)
• Surge protection for all Inputs by gas discharge tube (GDT)

Campbell Scientific Data Logger - CR6-WIFI

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 12x single-ended or 6x differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN, USB, RJ-45, Micro-SD card 
• WLAN Wi-Fi for short-range wireless IP communications based on 802.11 b/g/n, WPA/WPA2-Personal, WPA/WPA2-Enterprise Security, WEP
• 4 Mbytes SRAM memory (extendable)

Campbell Scientific Data Logger - CR6-RF422

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 12x single-ended or 6x differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN, USB, RJ-45, Micro-SD card 
• Internal RF422 modem (or optional for specific countries: RF407, RF412, RF451)
• 4 Mbytes SRAM memory (extendable)

Campbell Scientific Data Logger - CR350

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 4x multi-purpose analog input terminals: analog functions, digital I/O functions
• 2x pulse counting programmable terminals
• 2x configurable control digital I/O terminals
• 2x switched 12V OUT; 2x voltage excitation terminals
• 1x RS232, 1x RS-485, 1x USB Type C 2.0
• 50MB serial flash memory

Campbell Scientific Data Logger - CR310

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 6x single-ended or 3x differential freely programmable analog or digital IN & OUT
• 8x pulse counting terminals with 2x control terminals
• 7x configurable digital I/O terminals
• 2x switched 12V OUT; 2x voltage excitation terminals
• 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional)
• 30MB serial flash memory

Campbell Scientific Data Logger - CR300-RF422

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 6x single-ended or 3x differential freely programmable analog or digital IN & OUT
• 8x pulse counting terminals with 2x control terminals
• 7x configurable digital I/O terminals
• 1x switched 12V OUT; 1x voltage excitation terminals
• 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional), Wi-Fi (optional)
• with 868MHz SRD860 RADIO
• 30MB serial flash memory
• Integral surge and ESD protection
• Integrated 12 V battery solar charge regulator to charge batteries
• Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols
• Standard operating range of data logger -40° … +70°C
• Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications

Campbell Scientific Data Logger - CR300

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 6x single-ended or 3x differential freely programmable analog or digital IN & OUT
• 8x pulse counting terminals with 2x control terminals
• 7x configurable digital I/O terminals
• 1x switched 12V OUT; 1x voltage excitation terminals
• 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional), Wi-Fi (optional)
• 30MB serial flash memory
• Integral surge and ESD protection
• Integrated 12 V battery solar charge regulator to charge batteries
• Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols
• Standard operating range of data logger -40° … +70°C
• Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications

Campbell Scientific Data Logger - CR1000X

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 16x analogue single-ended or 8 differential Analog Inputs, 10x pulse counters, 8x digital IN/OUT (configurable), 4x analogue voltage (switched excitation mode or switched regulated voltage supply), 2x switched 12V 
• RS232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port, Wi-Fi (optional module)
• 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB

Campbell Scientific Data Logger - CR1000

• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 16x analogue single-ended or 8 differential IN
• 2x digital pulse counters IN
• 8x digital IN/OUT
• 3x analogue voltage OUT
• 1x switched 12V OUT
• RS232
• CS I/O PORT, SDI-12, Peripheral ports
• CF-card, USB, LAN, WLAN (optional)
• 2/4 Mbytes SRAM memory
• Surge protection for all Inputs by gas discharge tube (GDT)
• Surge protection for critical outputs by GDT or transient voltage suppression diodes
• Power feeding protected by transzorb diodes
• Grounding socket for electrostatic discharge (ESD) protection

Campbell Scientific Monitoring Platform - MeteoPV

• Purpose-built photovoltaic resource data platform
• Integrated surge and ESD protection
• SCADA ready

Campbell Scientific general-purpose, multiplexed analog measurement module - VOLT 116

• General-purpose, multiplexed analog measurement module
• 16 differential or 32 single-ended input channels with 2 excitation channels
• 2x switched 12V and 4x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific general-purpose, multiplexed analog measurement module - VOLT 108

• General-purpose, multiplexed analog measurement module
• 8 differential or 16 single-ended input channels with 2 excitation channels
• 1x switched 12V and 2x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific 20-Channel Thermocouple Module - TEMP 120

• Purpose-built thermocouple measurement module
• Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers 
• 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors
• Resolution of 0.015°C
• Handles extreme temperature environments and rapid thermal gradients
• Time base can be referenced either to GPS or a temperature-compensated real-time clock
• CPI DAQ connection for channel expansion
• USB 2.0 interface for PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Campbell Scientific 4-Channel Serial Input/Output Module - SDM-SIO4A

• Compatible with CR1000X and other models

Campbell Scientific 16-Channel Input/Output Module - SDM-IO16A

• Compatible with CR1000X and other models
• Connects to the data logger via three ports that can be shared with up to 15 other SDM devices
• Adds 16 digital I/O ports
• Operating Temperature: -40°C to 70°C

Campbell Scientific USB Storge Extension & Portable Configurator - SC115

• USB (2.0) interface with up to 2GB flash storage
• Allows Plug&Play field upgrades and configuration by using our Device Configuration utility
• Expands data logger storage by 2 GB, tandem operation with Compact Flash card possible
• Shuttles data, OS, and program files between Campbell Scientific dataloggers and a PC
• For CR800, CR850, CR1000, CR6, CR3000, CR5000, CR9000(X)

Campbell Scientific Wireless Networl Link Interface - NL241

• Connects directly to the peripheral port