Based on Campbell Scientific CR1000X Data Logger
• On demand our measurement systems will host an embedded Campbell Scientific CR1000X datalogger incl. programming and configuration.
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 16x analogue single-ended or 8 differential Analog Inputs
• 10x pulse counters
• 8x digital IN/OUT (configurable)
• 4x analogue voltage (switched excitation mode or switched regulated voltage supply)
• 2x switched 12V
• RS232
• CS I/O PORT to CSI peripherals
• USB
• Ethernet (LAN) port
• 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB
• Surge, Electrostatic Discharge and Lightning Protection for all critical Inputs and Outputs by gas discharge tube (GDT) or transient voltage suppression diodes
• Power feeding protected by transzorb diodes
• Grounding socket for surge, electrostatic discharge and lightning protection
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
Further options can optionally be booked, for example more or other sensors, (communication) interfaces and/or data logger programming, data monitoring, cloud services, IoT functionality, etc.
Campbell Scientific CR1000X Data Logger
Campbell Scientific releases some iconic data logger models, including the CR1000X. This datalogger precisely and reliably records, collects, analyses and shares various types of data. This data logger from Campbell Scientific comes with a myriad of uses, functions and flexibility, such as measuring and recording climatologic elements with exceptional accuracy and stability. For years, Campbell Scientific releases have posed all the challenges and remain the most computationally powerful, flexible and reliable data logging devices and systems on the planet.
read more »Campbell Scientific CR1000X Data Logger
Unlock the potential of your renewable energy projects with the Campbell Scientific CR1000X Data Logger. This advanced, industrial data logger is a cornerstone of precision in both wind and solar resource assessments and a Campbell Scientific flagship product. It is specifically designed to meet the rigorous demands of field measurements for Solar Resource Assessments (SRA) and Wind Resource Assessments (WRA), providing unparalleled accuracy and reliability.
Key Features
- Advanced Logging Capabilities: The Campbell Scientific CR1000X is ideal for both applications: wind dataloggers and solar dataloggers. It ensures precise data collection and analysis, which is essential for comprehensive wind measurements and wind resource assessments (WRA) and solar measurement for solar resource assessments (SRA).
- Robust Protection: Our measurement systems feature embedded Campbell Scientific CR1000X dataloggers, complete with programming and configuration. The system offers surge, electrostatic discharge, and lightning protection for all critical inputs and outputs using gas discharge tubes (GDT) or transient voltage suppression diodes. Power feeding is safeguarded by transzorb diodes, and a grounding socket is provided for enhanced protection.
- Versatile Applications: Whether you need a solar data logger or a wind data logger, the CR1000X is equipped to handle virtually unlimited data logging needs. Its robust industrial design and superior performance make it suitable for a wide range of applications, including detailed wind resource assessments and precise solar resource assessments.
- Comprehensive Data Management: The CR1000X ensures that your data is accurately captured and easily accessible for analysis. This makes it an invaluable tool for any renewable energy project, ensuring that you have the insights needed to optimize your energy production.
Why Choose the Campbell Scientific CR1000X?
- Reliability: The CR1000X is renowned for its reliability and durability, making it the preferred choice for professionals in the renewable energy sector. The technical availability in most of our measurement systems that employ a CR1000X is > 99%.
- Precision: With the Campbell Scientific CR1000X, you can be confident in the accuracy of your data, whether you are conducting wind measurements for WRA or solar measurements for SRA.
- Customization: On demand, our measurement systems can host an embedded Campbell Scientific CR1000X datalogger, including complete programming and configuration tailored to your specific needs. Using an SDM-IO16A 16-Channel Input / Output Module enables to add 15 other SDM devices respectively 16 digital I/O ports, increasing the measurement potential massively. A CR1000KD Keyboard and Display Screen rounds off the entire comfort of CR1000X data logger employment.
- Ruggedness: The CR1000X is a flagship data logger yielding highest manufacturing standards, product quality and durability. Only one datalogger out of hundreds may get broken from time to time; and even in such case the modular design enables that even repair of broken wind data loggers can be executed at an economically sound expense often.
- Warranty: For Campbell Scientific wind and solar data loggers CR1000X, in design of a PV1000X, we even dare to offer a 5-year product warranty, even if employed in harsh environments.
Applications
Solar Data Loggers
For solar resource assessment, the Campbell Scientific CR1000X serves as an exceptional solar data logger. With its outstanding accuracy and reliability, these dataloggers can measure and record solar radiation, reflection, sun shine duration, solar spectral distribution, temperature, humidity and many other critical parameters needed for industrial solar power generation and underlying analysis. By employing the CR1000X as your solar datalogger, one ensures highest data quality in terms of collection and storage, is crucial for optimizing solar power plant design and engineering parameters and its ultimate operational performance.
Wind Data Loggers
In wind resource assessment, the CR1000X excels as a wind data logger. It precisely captures parameters as wind speed, wind direction, temperature, humidity, pressure and other meteorological data essential for evaluating wind energy potentials. As a wind datalogger, it provides detailed insights that are vital for the development and planning of wind farms and power curve verification and testing of wind turbines.
Enhanced Protection and Durability
The Campbell Scientific CR1000X Data Logger is designed to withstand the harshest environmental conditions. With its surge, electrostatic discharge, and lightning protection, it ensures the longevity and reliability of your data logging equipment. Additionally, a grounding socket is provided to further safeguard against electrical disturbances. The operational temperature range is impressive and being available also with an extended temperature range, this data logger can even be operated from –55 °C to +85 °C!
Optimize Your Renewable Energy Assessments
Equip your renewable energy projects with the best in data logging technology. Choose the Campbell Scientific CR1000X Data Logger for accurate, reliable, and comprehensive data collection and analysis. Whether one is focusing on solar measurements or wind measurements, this state-of-the-art data logger will meet and exceed your expectations.
Ensure the success of your wind and solar resource assessments with the Campbell Scientific CR1000X, the industry standard for solar data loggers and wind data loggers.
Optimize your renewable energy assessments today with the Campbell Scientific CR1000X Data Logger—your key to precision and reliability in solar and wind data logging.
ProfEC Ventus is an officially recognized Campbell Scientific Partner. For more information, visit the ProfEC Ventus website in the USA or Germany.
CR1000X by Campbell Scientific is a low-powered data logging device that uses high-speed sensors and microSD card to measure and store a wide range of parameters. Additionally, it can analyze the data before storage and even goes ahead to control external devices, e.g. through PakBus and Modbus.
The datalogger CR1000X by Campbell Scientific can be operated by using up to 16 single-ended analog inputs (all individually configured), 8 configurable digital input and output terminals (maximum input frequency ≤ 1000 Hz), 10 pulse counters, 4 voltage excitation terminals and 2 witched 12 Volt terminals. The CR1000X data logger supports a variety of communication protocols like CPI, PakBus, SDM, SDI-12, Modbus, TCP, DNP3, UDP, NTCIP, NMEA 0183, I2C, SPI, and others, as well as internet protocols like Ethernet, PPP, CS I/O IP, RNDIS, ICMP/Ping, Auto-IP(APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, SNMPv3, NTP, Telnet, HTTP(S), FTP(S), SMTP/TLS, POP3/TLS, using communication ports such as Ethernet, USB Micro B, CS I/O, RS-232, CPI, RS-485.
This system uses a fast-paced feature that quickly captures data values and differentiates slightest of all changes. The data logger can serve as both, as Modbus master and Modbus slave. CR1000x also can connect to a SCADA system through a Modbus RS-485 protocol. The Campbell Scientific data logger CR1000X is equipped with a high-resolution AD-Converter (ADC) of 24 bit and native data storage of in total onboard 128 MB of flash and 4 MB battery-backed SRAM. The storage capacity can be expanded by up to 16 GB with removable microSD flash memory card! Several more periphery and extension modules make this data logger most flexible in scope and application.
The quality of this device tops off by a 3-year warranty term.
At a glance the CR1000X datalogger device can operate in extreme environmental conditions. The data logger CR1000X can be used in a temperature range of -55 to +85 degrees centigrade. By just connecting it directly to any USB port, the CR1000X can perfectly be employed for exacting wind resource measurements, solar resource measurements, weather stations, hydrometeorological stations and mesonet system, providing full flexibility, transparency and uttermost reliability and precision at a fair price.
CR1000Cal
For further information please contact us or look at Documents.
cr1000x-product-manual.pdf
cr1000x-getting-started-guide.pdf
eudoc-cr1000x.pdf
For further information please contact us or check the OEM homepage for most recent information.