• 650...1050 hPa • Calibrated (ISO 17025) with traceable calibration certificate and mark (ilac-MRA) • Output signal: 0...5V DC • Supply Voltage: 8 ... 32 V • Operating temperature: -40 ... 105°C
• 800...1050 hPa • Calibrated (ISO 17025) with traceable calibration certificate and mark (ilac-MRA) • Output signal: 0...5V DC • Supply Voltage: 8 ... 32 V • Operating temperature: -40 ... 105°C
• 3.1157.10.000 • 0...5V output, set 800...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.040 • 0...20mA output, set 600...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.041 • 4...20mA output, set 600...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.141 • 4...20mA output, set 800...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.140 • 0...20mA output, set 800...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 500...1100 hPa • Long-term stability ±0.1 hPa/year • Accuracy ±0.3 hPa at +20 °C • Traceable NIST calibration incl. certificate
• 500 ... 1100 hPa or 50 .... 1100 hPa pressure ranges with serial output • Different scalings between 500 ... 1100 hPa with analog output • Long-term stability ±0.1 hPa/year • Accuracy ±0.15 hPa at +20 °C • Traceable NIST calibration incl. certificate
• 500 ... 1100 hPa • Long-term stability ±0.1 hPa/year • Accuracy ±0.10 hPa at +20 °C • Traceable NIST calibration incl. certificate
• 500 ... 1100 hPa (optional range settings) • Long-term stability ±0.1 hPa/year • Accuracy ±0.15 hPa at +20 °C • Traceable NIST calibration incl. certificate
• BaroVUE10 • 500 ... 1100 hPa • Long-term stability ±0.1 hPa/year • Calibration Uncertainty ±0.15 hPa • Resolution 0.1 hPa
• K611PB • 600...1100 hPa • Frequency range: 1 - 500 Hz • Supply voltage: 3.3 - 30V • Accuracy ±0.52 hPa at +20 °C • Low energy consumption/Input current (1.8mA)
• 800 ... 1100 hPa • Accuracy (-10 ... 60 °C): ±1 % of Full Scale Output (~3 hPa) • Operating environmental conditions: 0 ... 98 % relative humidity • Long-term stability ±0.1 % of Full Scale Output/year (~0.3 hPa)
• 600...1100 hPa • Accuracy (-10 ... 60 °C): ±1% of Full Scale Output (~5 hPa) • Operating environmental conditions: 0 ... 98% relative humidity • Long-term stability ±0.1% of Full Scale Output/year (~0.5hPa)
• Supply Voltage: 5 ... 45 VDC • Power Consumption: 20 μA (12 V, normal use), 3 μA (12 V, always on) • Range: 400 ... 1200 hPa • Accuracy: ±0.2 hPa (400 ... 1100 hPa, –40 ... 85 °C) • Resolution: 1/64 hPa ≈ 0.0156 hPa • Interfaces: RS-485, RS-232, SDI-12, USB • Protocols: Modbus RTU/ASCII, SDI-12, USB-CDC
• Supply Voltage: 5 ... 45 VDC • Power Consumption (at 12 V): < 1mA (standby 40 μA) • Range: 600 ... 1100 hPa • Accuracy: ±0.2 hPa (600 ... 1100 hPa, –40 ... 85 °C) • Resolution: 1/64 hPa ≈ 0.0156 hPa • Output Voltage: 0 ... 2.5 or 0 ... 5 VDC • Long-Term Drift: ±0.05 ... 0.06 hPa
Barobox • In the barometer box, several barometer types can be located: Setra (278 / 276) , Vaisala (PTB110), Amonit (AB 60 / AB 00) etc. the box is vented by a membrane inlet to enable pressure equalization inside • Length x width x height: 80 x 80 x 51 mm • IP protection class: IP 54 • Operating range: -25 to 40 deg C • Outdoor Protection
• ilac-MRA accredited calibration • DAkkS accredited calibration • Compliant to recommendations of FGW TR6, IEC and MEASNET • Incl. calibration certificate
• Protects the measuring element against high wind speeds (> 5 m/s) and increased dust exposure • Required for exposed operating environments • Dimensions: Ø 20 x 25m m • Material: Stainless steel • Fits following models: 1.1006.54.080 1.1006.54.081 1.1006.54.740 1.1006.54.741 1.1006.54.760 1.1006.54.761 1.1006.54.780 1.1006.54.781
• Temperature: Measurement range: -40 ... 85 °C Accuracy (-40 … 85 °C, moved air > 2 m/s): ±0.1 °C • Relative Humidity: Measurement range: 0 ... 100 % rH Accuracy: 1.5 % rH • Pressure: Measurement range: 300 ... 1200 hPa Accuracy (@ -20 … 80°C @ 800...1100 hPa): ±0.25 hPa • Supply Voltage: 6 ... 30 V DC • Output: RS485, Half-duplex 8N1 (Baud rate configurable), Modbus RTU
• Temperature: Measurement range: -40 ... 85 °C Accuracy (-40 … 85 °C, moved air > 2 m/s): ±0.1 °C • Relative Humidity: Measurement range: 0 ... 100 % rH Accuracy: 1.5 % rH • Pressure: Measurement range: 300 ... 1200 hPa Accuracy (@ -20 … 80°C @ 800...1100 hPa): ±0.25 hPa • Supply Voltage: 6 ... 30 V DC • Output: RS485, Half-duplex 8N1 (Baud rate configurable), Thies ASCII
• Temperature: Measurement range: -40 ... 85 °C Accuracy (-40 … 85 °C, moved air > 2 m/s): ±0.1 °C • Relative Humidity: Measurement range: 0 ... 100 % rH Accuracy: 1.5 % rH • Pressure: Measurement range: 300 ... 1200 hPa Accuracy (@ -20 … 80°C @ 800...1100 hPa): ±0.25 hPa • Supply Voltage: 6 ... 30 V DC • Output: 0 ... 1 V, 3 Channels RS-485: Thies ASCII
• Temperature: Measurement range: -40 ... 85 °C Accuracy (-40 … 85 °C, moved air > 2 m/s): ±0.1 °C • Relative Humidity: Measurement range: 0 ... 100 % rH Accuracy: 1.5 % rH • Pressure: Measurement range: 300 ... 1200 hPa Accuracy (@ -20 … 80°C @ 800...1100 hPa): ±0.25 hPa • Supply Voltage: 15 ... 30 V DC • Output: 0 ... 10 V, 3 Channels RS-485: Thies ASCII
• Temperature: Measurement range: -40 ... 85 °C Accuracy (-40 … 85 °C, moved air > 2 m/s): ±0.1 °C • Relative Humidity: Measurement range: 0 ... 100 % rH Accuracy: 1.5 % rH • Pressure: Measurement range: 300 ... 1200 hPa Accuracy (@ -20 … 80°C @ 800...1100 hPa): ±0.25 hPa • Supply Voltage: 15 ... 30 V DC • Output: 4 ... 20 mA, 3 Channels RS-485: Thies ASCII
• ISO conform calibration by accredited Calibration Laboratory • Compliant to recommendations of FGW TR6, IEC and MEASNET • Incl. calibration certificate
• Pressure: 300 … 1200 hPa • Temperature: –50 … 60°C • Relative Humditiy: 0 … 100 %RH • Operating power consumption: 4 … 32 V • Digital output: RS485, 2-wire, half-duplex • Communication protocoll: UMB-Binary, UMB-ASCII, SDI-12, MODBUS • Protection type housing: IP66
• Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
• LiYCY (TP) BK • Manufactured with special PVC-based compound insulation and cores twisted to pairs • Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
{{.}}
{{{.}}}