Campbell Scientific Inc.
Campbell Scientific Inc.
https://www.campbellsci.de/
MesoPRO

MesoPRO
• 10-meter tower for long-term installations
• Measurements of wind speed. wind direction, air temperature, relative humidity, barometric pressure, precipitation, solar radiation, soil volumetric water content
• With rechargeable power supply and 50W solar panel

Preis auf Anfrage
Campbell Scientific CR310 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available
• 6x single-ended or 3x differential freely programmable analog or digital IN & OUT
• 8x pulse counting terminals with 2x control terminals
• 7x configurable digital I/O terminals
• 2x switched 12V OUT; 2x voltage excitation terminals

• 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional)
• 30MB serial flash memory
• Integral surge and ESD protection
• Integrated 12 V battery solar charge regulator to charge batteries
• Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols
• Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications

Preis auf Anfrage
Campbell Scientific CR300 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available
• 6x single-ended or 3x differential freely programmable analog or digital IN & OUT
• 8x pulse counting terminals with 2x control terminals
• 7x configurable digital I/O terminals
• 1x switched 12V OUT; 1x voltage excitation terminals

• 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional), Wi-Fi (optional)
• 30MB serial flash memory
• Integral surge and ESD protection
• Integrated 12 V battery solar charge regulator to charge batteries
• Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols
• Standard operating range of data logger -40° … +70°C
• Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications

Preis auf Anfrage
Campbell Scientific CR6-RF4XX Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 12x single-ended or 6x differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN, USB, RJ-45, Micro-SD card 

• Internal RF422 modem (or optional for specific countries: RF407, RF412, RF451)
• 4 Mbytes SRAM memory (extendable)
• Surge protection for critical Outputs by GDT or transient voltage suppression diodes
• Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)

Preis auf Anfrage
Campbell Scientific CR6-WIFI Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 12x single-ended or 6x differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN, USB, RJ-45, Micro-SD card 

• WLAN Wi-Fi for short-range wireless IP communications based on 802.11 b/g/n, WPA/WPA2-Personal, WPA/WPA2-Enterprise Security, WEP
• 4 Mbytes SRAM memory (extendable)
• Surge protection for critical Outputs by GDT or transient voltage suppression diodes
• Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)

Preis auf Anfrage
Campbell Scientific CR6 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 12x single-ended or 6x differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN, USB, RJ-45, Micro-SD card 
• 4 Mbytes SRAM memory (extendable)
• Surge protection for critical Outputs by GDT or transient voltage suppression diodes
• Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)

Preis auf Anfrage
Campbell Scientific CR1000X Data Logger

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 16x analogue single-ended or 8 differential Analog Inputs, 10x pulse counters, 8x digital IN/OUT (configurable), 4x analogue voltage (switched excitation mode or switched regulated voltage supply), 2x switched 12V 
• RS232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port, Wi-Fi (optional module)
• 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB
• Surge, Electrostatic Discharge and Lightning Protection for all critical Inputs and Outputs
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
MetPRO

MetPRO
• 3 m portable tripod suitable for long-term and temporary deployments on flat or uneven terrain
• Measurements of wind speed. wind direction, air temperature, relative humidity, barometric pressure, precipitation, solar radiation, soil volumetric water content
• With rechargeable power supply and 20W solar panel

Preis auf Anfrage
Campbell Scientific CR350 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available
• 4x multi-purpose analog input terminals: analog functions, digital I/O functions
• 2x pulse counting programmable terminals
• 2x configurable control digital I/O terminals
• 2x switched 12V OUT; 2x voltage excitation terminals

• 1x RS232, 1x RS-485, 1x USB Type C 2.0
• 50MB serial flash memory
• Integral surge and ESD protection
• Integrated 12 V battery solar charge regulator to charge batteries
• Connect with PakBus, Modbus, DNP3, SDI-12, and other standard communication protocols
• Standard operating range of data logger -40° … +70°C

Preis auf Anfrage
Campbell Scientific CR1000Xe Data Logger
TOP

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 16x analogue single-ended or 8 differential Analog Inputs, 10x pulse counters, 8x digital IN/OUT (configurable), 4x analogue voltage (switched excitation mode or switched regulated voltage supply), 2x switched 12V 
• RS485/232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port, Wi-Fi (optional module)
• 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB
• Surge, Electrostatic Discharge and Lightning Protection for all critical Inputs and Outputs
• Power in 9.6V to 36VDC
• Stainless steel type-D connectors and gold plating improvements on RJ45s
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
BaroVUE10

• BaroVUE10
• 500 ... 1100 hPa
• Long-term stability ±0.1 hPa/year
• Calibration Uncertainty ±0.15 hPa
• Resolution 0.1 hPa

Preis auf Anfrage
WxPRO

 WxPRO
• Portable tripod suitable for long-term and temporary deployments
• Measurements of wind speed. wind direction, air temperature, relative humidity, barometric pressure, precipitation, solar radiation
• With rechargeable power supply and 10W solar panel

Preis auf Anfrage
SunScout

SunScout
• High-quality solar resource assessment system

• Mounted in Galvanized-Steel-Tubing Tripod with Grounding Kit
• Measurements of Irradiance such as Global horizontal irradiance (GHI), Fixed plane of array (POA), Calculated direct normal irradiance (DNI), and Albedo; Soiling; and Meteorological such as Air temperature, Barometric pressure, Relative humidity, Precipitation, Wind direction, and Wind speed are available
• Power supply consisting of solar PV panels and battery bank will be sized accordingly

Preis auf Anfrage
Solar Panel Back-of-Module Temperature Sensor Campbell Scientific CS241

CS241
• Pt-1000
• Accuracy: ± (0.15 + 0.002T)°C
• Uncertainty: ± 0.3° to 0.4°C when using CR1000X or PV1000X
• Operating temperature: -40° to +150°C
• Compliant with IEC 60751
• Factory Calibrated

Preis auf Anfrage
Temperature Sensor Campbell Scientific CS241

CS241
• Pt-1000
• Accuracy: ± (0.15 + 0.002T)°C
• Uncertainty: ± 0.3° to 0.4°C when using CR1000X or PV1000X
• Operating temperature: -40° to +150°C
• Compliant with IEC 60751
• Factory Calibrated

Preis auf Anfrage
DustSENS

DustSENS
• Measures and calculates the soiling-loss index to evaluate and manage the impact of soiling of photovoltaic (PV) power plant performance

• Typically measures Short-circuit current, Back-of-module temperature, Effective irradiance, Soiling ratio, Daily soiling-loss index, and Soiling
• Operating temperature range: -40° to +150°C

Preis auf Anfrage
Solar1000

SOLAR1000
• Automated data acquisition system specifically designed for solar monitoring applications

• Measurements of Air temperature, Solar radiation—global horizontal (GH), Solar radiation—plane of array (POA), Surface temperature—back of panel, Wind direction, Wind speed, Precipitation, and Barometric pressure
• AC and/or Autonomous DC Power Supply

Preis auf Anfrage
CSP100

CSP100
• CAISO complaint meteorological station for concentrated-solar-power generating facilities

• Measurements of Direct Normal Irradiance (DNI), Diffuse Horizontal Irradiance (DHI), Global Horizontal Irradiance (GHI), Wind speed, Wind direction, Air temperature, Relative humidity, Barometric pressure, Precipitation, and Solar position
• Provides a battery back system that allows data collection during power outages and network failure

Preis auf Anfrage
UTILITY100

UTILITY100
• Designed for the utility market and SCADA operations that rely on DNP3 and/or Modbus protocols

• Measurements of Air temperature, Relative humidity, Wind speed, Wind direction, Precipitation, Barometric pressure, and Solar radiation—sun plus sky radiation
• Battery-backed system

Preis auf Anfrage
Campbell Scientific CR1000 - Data Logger embedded in our measurement systems

• 16x analogue single-ended or 8 differential IN
• 2x digital pulse counters IN
• 8x digital IN/OUT
• 3x analogue voltage OUT
• 1x switched 12V OUT
• RS232
• CS I/O PORT, SDI-12, Peripheral ports
• CF-card, USB, LAN, WLAN (optional)
• 2/4 Mbytes SRAM memory
• Surge protection for all Inputs by gas discharge tube (GDT)
• Surge protection for critical outputs by GDT or transient voltage suppression diodes
• Power feeding protected by transzorb diodes
• Grounding socket for electrostatic discharge (ESD) protection

Preis auf Anfrage
Campbell Scientific CR800 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available
• 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT
• RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available
• 2/4 Mbytes SRAM memory (optionally extendable)
• Surge protection for all Inputs by gas discharge tube (GDT)

Preis auf Anfrage
Campbell Scientific CR850 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT
• RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available
• 2/4 Mbytes SRAM memory (optionally extendable)
​• Keypad and LCD Display
• Surge protection for all Inputs by gas discharge tube (GDT)
• Standard operating range of data logger -25° … +50°C (optionally extended: -30° … +80°C)

Preis auf Anfrage
Campbell Scientific - SDM-IO16A 16-Channel Input/Output Module

• Compatible with PV1000X and other models
• Connects to the data logger via three ports that can be shared with up to 15 other SDM devices
• Adds 16 digital I/O ports
• Operating Temperature: -40°C to 70°C

Preis auf Anfrage
Multiplexer AM16/32B

• Increases the number of sensors the data logger can measure
• Allows to multiplex up to 64 sensors
• Decreases cost of cabling individual sensors
• Electrical surge protection
• Operating voltage: 9-16 VDC
• Operating temperature: -25°C to 50°C (standard), -55°C to 85°C (extended)

Preis auf Anfrage
CD100 Static Keyboard & Display

• Keypad with display for easy access
• Compatible with PV1000X
• Allows to check Datalogger status, change ports, enter numeric data and view or plot sensor data
• Operating temperature: -45°C to 85°C 

Preis auf Anfrage
Campbell Scientific SC115 USB Storge Extension & Portable Configurator

• USB (2.0) interface with up to 2GB flash storage
• Allows Plug&Play field upgrades and configuration by using our Device Configuration utility
• Expands data logger storage by 2 GB, tandem operation with Compact Flash card possible
• Shuttles data, OS, and program files between Campbell Scientific dataloggers and a PC
• For CR800, CR850, CR1000, CR6, CR3000, CR5000, CR9000(X)

Preis auf Anfrage
Campbell Scientific NL116 Ethernet and CF Card Module

• Ethernet Interface
• Allows communications over local networks via TCP/IP

• Compact Flash Module
• Expands data logger storage via CompactFlash® by up to 2 GB

• For CR1000 and CR3000
• Connects directly to the peripheral port

Preis auf Anfrage
VOLT108 Module

• General-purpose, multiplexed analog measurement module
• 8 differential or 16 single-ended input channels with 2 excitation channels
• 1x switched 12V and 2x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation

• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
VOLT116 Module

• General-purpose, multiplexed analog measurement module
• 16 differential or 32 single-ended input channels with 2 excitation channels
• 2x switched 12V and 4x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation

• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
TEMP120 Module

• Purpose-built thermocouple measurement module
• Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers 
• 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors
• Resolution of 0.015°C
• Handles extreme temperature environments and rapid thermal gradients
• Time base can be referenced either to GPS or a temperature-compensated real-time clock

• CPI DAQ connection for channel expansion
• USB 2.0 interface for PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
Campbell Scientific CFM100 Compact Flash Module

• Compact Flash Module
• For CR1000 and CR3000
• Expands data logger storage via CompactFlash® by up to 2 GB
• Connects directly to the peripheral port

Preis auf Anfrage
Campbell Scientific CURS100

CURS100
• Enables a Campbell Scientific data logger to measure a sensor with current output signal, e.g. 4-20 mA; converts the current signal to voltage signal

 

Preis auf Anfrage
Campbell Scientific 4WPB100

4WPB100
• Provides completion resistors to measure 100-Ohm platinum resistive thermometer (PRT) using the half-bridge four-wire measurement method on a Campbell Scientific data logger

 

Preis auf Anfrage
Campbell Scientific 4WPB100

4WPB1K
• Provides completion resistors to measure 1000-Ohm platinum resistive thermometer (PRT) using the half-bridge four-wire measurement method on a Campbell Scientific data logger

 

Preis auf Anfrage
Campbell Scientific CR1000KD Portable Keyboard and Display Screen

• 8 lines x 21 characters with 16-character keyboard
• Powered by the data logger power supply
• Allows to check the datalogger's status, display or plot sensor readings and stored values, and enter numeric data or change port/flag state
• Supports custom menus
• Can be easily carried from station to station in a datalogger network

Preis auf Anfrage
CSci MeteoPV

• Purpose-built photovoltaic resource data platform
• Ideal for distributed PV monitoring and functioning as a plane-of-array (POA), albedo, and soiling secondary weather station
• Intuitive onboard user interface accessed by a web browser
• SCADA ready with Modbus RTU and Modbus TCP/IP
• Internal Memory: 3 months' storage of 1- and 10-min average

Preis auf Anfrage
CSci MeteoPV

• Purpose-built photovoltaic resource data platform
• Ideal for distributed PV monitoring and functioning as a plane-of-array (POA), albedo, and soiling secondary weather station
• Intuitive onboard user interface accessed by a web browser
• SCADA ready with Modbus RTU and Modbus TCP/IP
• Internal Memory: 3 months' storage of 1- and 10-min average

Preis auf Anfrage
Campbell Scientific CR1000KD Portable Keyboard and Display Screen

• 8 lines x 21 characters with 16-character keyboard
• Powered by the data logger power supply
• Allows to check the datalogger's status, display or plot sensor readings and stored values, and enter numeric data or change port/flag state
• Supports custom menus
• Can be easily carried from station to station in a datalogger network

Preis auf Anfrage
Campbell Scientific CFM100 Compact Flash Module

• Compact Flash Module
• For CR1000 and CR3000
• Expands data logger storage via CompactFlash® by up to 2 GB
• Connects directly to the peripheral port

Preis auf Anfrage
Campbell Scientific NL116 Ethernet and CF Card Module

• Ethernet Interface
• Allows communications over local networks via TCP/IP

• Compact Flash Module
• Expands data logger storage via CompactFlash® by up to 2 GB

• For CR1000 and CR3000
• Connects directly to the peripheral port

Preis auf Anfrage
Campbell Scientific SC115 USB Storge Extension & Portable Configurator

• USB (2.0) interface with up to 2GB flash storage
• Allows Plug&Play field upgrades and configuration by using our Device Configuration utility
• Expands data logger storage by 2 GB, tandem operation with Compact Flash card possible
• Shuttles data, OS, and program files between Campbell Scientific dataloggers and a PC
• For CR800, CR850, CR1000, CR6, CR3000, CR5000, CR9000(X)

Preis auf Anfrage
VOLT108 Module

• General-purpose, multiplexed analog measurement module
• 8 differential or 16 single-ended input channels with 2 excitation channels
• 1x switched 12V and 2x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation

• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
VOLT116 Module

• General-purpose, multiplexed analog measurement module
• 16 differential or 32 single-ended input channels with 2 excitation channels
• 2x switched 12V and 4x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation

• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
TEMP120 Module

• Purpose-built thermocouple measurement module
• Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers 
• 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors
• Resolution of 0.015°C
• Handles extreme temperature environments and rapid thermal gradients
• Time base can be referenced either to GPS or a temperature-compensated real-time clock

• CPI DAQ connection for channel expansion
• USB 2.0 interface for PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
1 bis 58 (von insgesamt 58)