• Calibration certificate • 12x single-ended or 6xy differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • LAN • USB • RJ-45 • Micro-SD card • 4 Mbytes SRAM memory • Surge protection for all Inputs by gas discharge tube (GDT) • Surge protection for critical Oututs by GDT or transient voltage suppression diodes • Power feeding protected by tranzorb diodes • Grounding socket for electrostatic discharge (ESD) protection
• 16x analogue single-ended or 8 differential IN • 2x digital pulse counters IN • 8x digital IN/OUT • 3x analogue voltage OUT • 1x switched 12V OUT • RS232 • CS I/O PORT, SDI-12, Peripheral ports • CF-card, USB, LAN, WLAN (optional) • 2/4 Mbytes SRAM memory • Surge protection for all Inputs by gas discharge tube (GDT) • Surge protection for critical outputs by GDT or transient voltage suppression diodes • Power feeding protected by transzorb diodes • Grounding socket for electrostatic discharge (ESD) protection
• 6x analog single-ended or 3 differential IN • 2x digital pulse counters IN • 4x digital IN/OUT • 3x analog voltage OUT • 1x switched 12V OUT • RS232 • CS I/O PORT • 2/4 Mbytes SRAM memory • Surge protection for all Inputs by gas discharge tube (GDT) • Power feeding protected by tranzorb diodes • Grounding socket for electrostatic discharge (ESD) protection
• Spectral range: 360 to 1120 nm (wavelengths where response is 10% of max) • 0...2000 W m-2 (full sunlight ≈1000 W m-2) • Incl. calibration certificate • Accuracy: ±5% for daily total radiation • Self-powered • For Global Horizontal Irradiance (GHI) measurements (W/m2)
• 6x analog single-ended or 3 differential IN • 2x digital pulse counters IN • 4x digital IN/OUT • 3x analog voltage OUT • 1x switched 12V OUT • RS232 • CS I/O PORT • 2/4 Mbytes SRAM memory • Keypad • LCD Display • Surge protection for all Inputs by gas discharge tube (GDT) • Power feeding protected by tranzorb diodes • Grounding socket for electrostatic discharge (ESD) protection
• Calibration certificate (standards traceable to U.K.A.S accreditation service) • 16x analogue single-ended or 8 differential Analog Inputs • 10x pulse counters • 8x digital IN/OUT (configurable) • 4x analogue voltage (switched excitation mode or switched regulated voltage supply) • 2x switched 12V • RS232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port • 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB • Surge, Electrostatic Discharge and Lightning Protection for all critical Inputs and Outputs • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• CR6-RF422 • Calibration certificate • 12x single-ended or 6xy differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • Internal RF422 morem or optional for specific countries: RF407, RF412, RF451 • LAN • USB • RJ-45 • Micro-SD card • 4 Mbytes SRAM memory • Surge protection for all Inputs by gas discharge tube (GDT) • Surge protection for critical Oututs by GDT or transient voltage suppression diodes • Power feeding protected by tranzorb diodes • Grounding socket for electrostatic discharge (ESD) protection
• CR6-WIFI • Calibration certificate • 12x single-ended or 6xy differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • WLAN WIFI for short-range wireless IP communications based on 802.11 b/g/n, WPA/WPA2-Personal, WPA/WPA2-Enterprise Security, WEP • USB • RJ-45 • Micro-SD card • 4 Mbytes SRAM memory • Surge protection for all Inputs by gas discharge tube (GDT) • Surge protection for critical Oututs by GDT or transient voltage suppression diodes • Power feeding protected by tranzorb diodes • Grounding socket for electrostatic discharge (ESD) protection
• General-purpose, multiplexed analog measurement module • 8 differential or 16 single-ended input channels with 2 excitation channels • 1x switched 12V and 2x switched 5V • Channel count expansion via the CPI bus • USB 2.0 interface for direct-to-PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Compact Flash Module • For CR1000 and CR3000 • Expands data logger storage via CompactFlash® by up to 2 GB • Connects directly to the peripheral port
• Ethernet Interface • Allows communications over local networks via TCP/IP • Compact Flash Module • Expands data logger storage via CompactFlash® by up to 2 GB • For CR1000 and CR3000 • Connects directly to the peripheral port
• USB (2.0) interface with up to 2GB flash storage • Allows Plug&Play field upgrades and configuration by using our Device Configuration utility • Expands data logger storage by 2 GB, tandem operation with Compact Flash card possible • Shuttles data, OS, and program files between Campbell Scientific dataloggers and a PC • For CR800, CR850, CR1000, CR6, CR3000, CR5000, CR9000(X)
• 8 lines x 21 characters with 16-character keyboard • Powered by the data logger power supply • Allows to check the datalogger's status, display or plot sensor readings and stored values, and enter numeric data or change port/flag state • Supports custom menus • Can be easily carried from station to station in a datalogger network
• Set-up easily with PC software and USB connectivity • Ideal for small applications requiring long-term, remote monitoring and control • Measure smart sensors using RS-232 or SDI-12 • 6x single-ended or 3x differential freely programmable analog or digital IN & OUT • 8x pulse counting terminals with 2x control terminals • 7x configurable digital I/O terminals • 2x switched 12V OUT; 2x voltage excitation terminals • 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 • 30MB serial flash memory • Integral surge and ESD protection • Integrated 12 V battery solar charge regulator to charge batteries • Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols • Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications
• One of the most computationally powerful data-acquisition devices from Campbell Scientific • 24 bit and 32 bit ADC • An all-digital measurement and control DAQ • 8x digital I/O terminals (configurable) • 4 General-purpose CAN channels • 2x switched 12V • EPI port switch for high-speed connection to all GRANITE modules • Built-in GPS for network synchronization • Built-in Wi-Fi • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• One of the most computationally powerful data-acquisition devices from Campbell Scientific • 24 bit and 32 bit ADC • An all-digital measurement and control DAQ • 8x digital I/O terminals (configurable) • 2x switched 12V • EPI port switch for high-speed connection to all GRANITE modules • Built-in GPS for network synchronization • Built-in Wi-Fi • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• General-purpose, multiplexed analog measurement module • 16 differential or 32 single-ended input channels with 2 excitation channels • 2x switched 12V and 4x switched 5V • Channel count expansion via the CPI bus • USB 2.0 interface for direct-to-PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Purpose-built thermocouple measurement module • Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers • 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors • Resolution of 0.015°C • Handles extreme temperature environments and rapid thermal gradients • Time base can be referenced either to GPS or a temperature-compensated real-time clock • CPI DAQ connection for channel expansion • USB 2.0 interface for PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Affordable all-in-one meteorological sensor • All the common meteorological measurements with one simple digital (SDI-12) output • Less than 1 mA at 12 Vdc average current, making it ideal for solar-powered sites • Integrated tilt sensor helps assure that the sensor stays level over time • Low maintenance—no moving parts significantly reduces maintenance cost and time • No sensor configuration required • Compact design for quick, low-impact installation • Compatible with all modern Campbell Scientific data loggers • Detachable cable facilitates field replacement
{{.}}
{{{.}}}