• MesoPRO • 10-meter tower for long-term installations • Measurements of wind speed. wind direction, air temperature, relative humidity, barometric pressure, precipitation, solar radiation, soil volumetric water content • With rechargeable power supply and 50W solar panel
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 6x single-ended or 3x differential freely programmable analog or digital IN & OUT • 8x pulse counting terminals with 2x control terminals • 7x configurable digital I/O terminals • 2x switched 12V OUT; 2x voltage excitation terminals • 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional) • 30MB serial flash memory • Integral surge and ESD protection • Integrated 12 V battery solar charge regulator to charge batteries • Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols • Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 6x single-ended or 3x differential freely programmable analog or digital IN & OUT • 8x pulse counting terminals with 2x control terminals • 7x configurable digital I/O terminals • 1x switched 12V OUT; 1x voltage excitation terminals • 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional), Wi-Fi (optional) • 30MB serial flash memory • Integral surge and ESD protection • Integrated 12 V battery solar charge regulator to charge batteries • Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols • Standard operating range of data logger -40° … +70°C • Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 12x single-ended or 6x differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • LAN, USB, RJ-45, Micro-SD card • Internal RF422 modem (or optional for specific countries: RF407, RF412, RF451) • 4 Mbytes SRAM memory (extendable) • Surge protection for critical Outputs by GDT or transient voltage suppression diodes • Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 12x single-ended or 6x differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • LAN, USB, RJ-45, Micro-SD card • WLAN Wi-Fi for short-range wireless IP communications based on 802.11 b/g/n, WPA/WPA2-Personal, WPA/WPA2-Enterprise Security, WEP • 4 Mbytes SRAM memory (extendable) • Surge protection for critical Outputs by GDT or transient voltage suppression diodes • Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 12x single-ended or 6x differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • LAN, USB, RJ-45, Micro-SD card • 4 Mbytes SRAM memory (extendable) • Surge protection for critical Outputs by GDT or transient voltage suppression diodes • Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 16x analogue single-ended or 8 differential Analog Inputs, 10x pulse counters, 8x digital IN/OUT (configurable), 4x analogue voltage (switched excitation mode or switched regulated voltage supply), 2x switched 12V • RS232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port, Wi-Fi (optional module) • 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB • Surge, Electrostatic Discharge and Lightning Protection for all critical Inputs and Outputs • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• MetPRO • 3 m portable tripod suitable for long-term and temporary deployments on flat or uneven terrain • Measurements of wind speed. wind direction, air temperature, relative humidity, barometric pressure, precipitation, solar radiation, soil volumetric water content • With rechargeable power supply and 20W solar panel
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 4x multi-purpose analog input terminals: analog functions, digital I/O functions • 2x pulse counting programmable terminals • 2x configurable control digital I/O terminals • 2x switched 12V OUT; 2x voltage excitation terminals • 1x RS232, 1x RS-485, 1x USB Type C 2.0 • 50MB serial flash memory • Integral surge and ESD protection • Integrated 12 V battery solar charge regulator to charge batteries • Connect with PakBus, Modbus, DNP3, SDI-12, and other standard communication protocols • Standard operating range of data logger -40° … +70°C
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 16x analogue single-ended or 8 differential Analog Inputs, 10x pulse counters, 8x digital IN/OUT (configurable), 4x analogue voltage (switched excitation mode or switched regulated voltage supply), 2x switched 12V • RS485/232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port, Wi-Fi (optional module) • 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB • Surge, Electrostatic Discharge and Lightning Protection for all critical Inputs and Outputs • Power in 9.6V to 36VDC • Stainless steel type-D connectors and gold plating improvements on RJ45s • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• BaroVUE10 • 500 ... 1100 hPa • Long-term stability ±0.1 hPa/year • Calibration Uncertainty ±0.15 hPa • Resolution 0.1 hPa
• One of the most computationally powerful data-acquisition devices from Campbell Scientific • 24 bit and 32 bit ADC • An all-digital measurement and control DAQ • 8x digital I/O terminals (configurable) • 4 General-purpose CAN channels • 2x switched 12V • EPI port switch for high-speed connection to all GRANITE modules • Built-in GPS for network synchronization • Built-in Wi-Fi • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• One of the most computationally powerful data-acquisition devices from Campbell Scientific • 24 bit and 32 bit ADC • An all-digital measurement and control DAQ • 8x digital I/O terminals (configurable) • 2x switched 12V • EPI port switch for high-speed connection to all GRANITE modules • Built-in GPS for network synchronization • Built-in Wi-Fi • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• An all-digital measurement and control DAQ • 24-bit ADC • 12x individually configured inputs for analog or digital functions • 16x terminals configurable for digital I/O • Built-in Wi-Fi and USB Micro-B for computer connectivity • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• WxPRO • Portable tripod suitable for long-term and temporary deployments • Measurements of wind speed. wind direction, air temperature, relative humidity, barometric pressure, precipitation, solar radiation • With rechargeable power supply and 10W solar panel
• SunScout • High-quality solar resource assessment system • Mounted in Galvanized-Steel-Tubing Tripod with Grounding Kit • Measurements of Irradiance such as Global horizontal irradiance (GHI), Fixed plane of array (POA), Calculated direct normal irradiance (DNI), and Albedo; Soiling; and Meteorological such as Air temperature, Barometric pressure, Relative humidity, Precipitation, Wind direction, and Wind speed are available • Power supply consisting of solar PV panels and battery bank will be sized accordingly
• CS241 • Pt-1000 • Accuracy: ± (0.15 + 0.002T)°C • Uncertainty: ± 0.3° to 0.4°C when using CR1000X or PV1000X • Operating temperature: -40° to +150°C • Compliant with IEC 60751 • Factory Calibrated
• DustSENS • Measures and calculates the soiling-loss index to evaluate and manage the impact of soiling of photovoltaic (PV) power plant performance • Typically measures Short-circuit current, Back-of-module temperature, Effective irradiance, Soiling ratio, Daily soiling-loss index, and Soiling • Operating temperature range: -40° to +150°C
• SOLAR1000 • Automated data acquisition system specifically designed for solar monitoring applications • Measurements of Air temperature, Solar radiation—global horizontal (GH), Solar radiation—plane of array (POA), Surface temperature—back of panel, Wind direction, Wind speed, Precipitation, and Barometric pressure • AC and/or Autonomous DC Power Supply
• CSP100 • CAISO complaint meteorological station for concentrated-solar-power generating facilities • Measurements of Direct Normal Irradiance (DNI), Diffuse Horizontal Irradiance (DHI), Global Horizontal Irradiance (GHI), Wind speed, Wind direction, Air temperature, Relative humidity, Barometric pressure, Precipitation, and Solar position • Provides a battery back system that allows data collection during power outages and network failure
• UTILITY100 • Designed for the utility market and SCADA operations that rely on DNP3 and/or Modbus protocols • Measurements of Air temperature, Relative humidity, Wind speed, Wind direction, Precipitation, Barometric pressure, and Solar radiation—sun plus sky radiation • Battery-backed system
• 16x analogue single-ended or 8 differential IN • 2x digital pulse counters IN • 8x digital IN/OUT • 3x analogue voltage OUT • 1x switched 12V OUT • RS232 • CS I/O PORT, SDI-12, Peripheral ports • CF-card, USB, LAN, WLAN (optional) • 2/4 Mbytes SRAM memory • Surge protection for all Inputs by gas discharge tube (GDT) • Surge protection for critical outputs by GDT or transient voltage suppression diodes • Power feeding protected by transzorb diodes • Grounding socket for electrostatic discharge (ESD) protection
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT • RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available • 2/4 Mbytes SRAM memory (optionally extendable) • Surge protection for all Inputs by gas discharge tube (GDT)
• Once powered up, the measurement automatically starts • 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT • RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available • 2/4 Mbytes SRAM memory (optionally extendable) • Keypad and LCD Display • Surge protection for all Inputs by gas discharge tube (GDT) • Standard operating range of data logger -25° … +50°C (optionally extended: -30° … +80°C)
• Compatible with PV1000X and other models • Connects to the data logger via three ports that can be shared with up to 15 other SDM devices • Adds 16 digital I/O ports • Operating Temperature: -40°C to 70°C
• Increases the number of sensors the data logger can measure • Allows to multiplex up to 64 sensors • Decreases cost of cabling individual sensors • Electrical surge protection • Operating voltage: 9-16 VDC • Operating temperature: -25°C to 50°C (standard), -55°C to 85°C (extended)
• Keypad with display for easy access • Compatible with PV1000X • Allows to check Datalogger status, change ports, enter numeric data and view or plot sensor data • Operating temperature: -45°C to 85°C
• USB (2.0) interface with up to 2GB flash storage • Allows Plug&Play field upgrades and configuration by using our Device Configuration utility • Expands data logger storage by 2 GB, tandem operation with Compact Flash card possible • Shuttles data, OS, and program files between Campbell Scientific dataloggers and a PC • For CR800, CR850, CR1000, CR6, CR3000, CR5000, CR9000(X)
• Ethernet Interface • Allows communications over local networks via TCP/IP • Compact Flash Module • Expands data logger storage via CompactFlash® by up to 2 GB • For CR1000 and CR3000 • Connects directly to the peripheral port
• General-purpose, multiplexed analog measurement module • 8 differential or 16 single-ended input channels with 2 excitation channels • 1x switched 12V and 2x switched 5V • Channel count expansion via the CPI bus • USB 2.0 interface for direct-to-PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• General-purpose, multiplexed analog measurement module • 16 differential or 32 single-ended input channels with 2 excitation channels • 2x switched 12V and 4x switched 5V • Channel count expansion via the CPI bus • USB 2.0 interface for direct-to-PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Purpose-built thermocouple measurement module • Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers • 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors • Resolution of 0.015°C • Handles extreme temperature environments and rapid thermal gradients • Time base can be referenced either to GPS or a temperature-compensated real-time clock • CPI DAQ connection for channel expansion • USB 2.0 interface for PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Compact Flash Module • For CR1000 and CR3000 • Expands data logger storage via CompactFlash® by up to 2 GB • Connects directly to the peripheral port
• CURS100 • Enables a Campbell Scientific data logger to measure a sensor with current output signal, e.g. 4-20 mA; converts the current signal to voltage signal
• 4WPB100 • Provides completion resistors to measure 100-Ohm platinum resistive thermometer (PRT) using the half-bridge four-wire measurement method on a Campbell Scientific data logger
• 4WPB1K • Provides completion resistors to measure 1000-Ohm platinum resistive thermometer (PRT) using the half-bridge four-wire measurement method on a Campbell Scientific data logger
• 8 lines x 21 characters with 16-character keyboard • Powered by the data logger power supply • Allows to check the datalogger's status, display or plot sensor readings and stored values, and enter numeric data or change port/flag state • Supports custom menus • Can be easily carried from station to station in a datalogger network
• Purpose-built photovoltaic resource data platform • Ideal for distributed PV monitoring and functioning as a plane-of-array (POA), albedo, and soiling secondary weather station • Intuitive onboard user interface accessed by a web browser • SCADA ready with Modbus RTU and Modbus TCP/IP • Internal Memory: 3 months' storage of 1- and 10-min average
• Affordable all-in-one meteorological sensor • All the common meteorological measurements with one simple digital (SDI-12) output • Less than 1 mA at 12 Vdc average current, making it ideal for solar-powered sites • Integrated tilt sensor helps assure that the sensor stays level over time • Low maintenance—no moving parts significantly reduces maintenance cost and time • No sensor configuration required • Compact design for quick, low-impact installation • Compatible with all modern Campbell Scientific data loggers • Detachable cable facilitates field replacement
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 12x single-ended or 6x differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • LAN, USB, RJ-45, Micro-SD card • 4 Mbytes SRAM memory (extendable) • Surge protection for critical Outputs by GDT or transient voltage suppression diodes • Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C) • Soil moisture hygrometer to measure and monitor water content in soil (5% … 95%), operating temperature range from -65°C … 150°C • Waterproof digital temperature sensor to measure temperature of many liquids and gases at an operating temperature range from -55°C … 125°C, ±0.5°C accuracy from -10°C to +85°C and ±0.15°C accuracy at from 0°C to 35°C
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 12x single-ended or 6x differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • LAN, USB, RJ-45, Micro-SD card • WLAN Wi-Fi for short-range wireless IP communications based on 802.11 b/g/n, WPA/WPA2-Personal, WPA/WPA2-Enterprise Security, WEP • 4 Mbytes SRAM memory (extendable) • Surge protection for critical Outputs by GDT or transient voltage suppression diodes • Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C) • Soil moisture hygrometer to measure and monitor water content in soil (5% … 95%), operating temperature range from -65°C … 150°C • Waterproof digital temperature sensor to measure temperature of many liquids and gases at an operating temperature range from -55°C … 125°C, ±0.5°C accuracy from -10°C to +85°C and ±0.15°C accuracy at from 0°C to 35°C
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 12x single-ended or 6x differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • LAN, USB, RJ-45, Micro-SD card • Internal RF422 modem (or optional for specific countries: RF407, RF412, RF451) • 4 Mbytes SRAM memory (extendable) • Surge protection for critical Outputs by GDT or transient voltage suppression diodes • Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C) • Soil moisture hygrometer to measure and monitor water content in soil (5% … 95%), operating temperature range from -65°C … 150°C • Waterproof digital temperature sensor to measure temperature of many liquids and gases at an operating temperature range from -55°C … 125°C, ±0.5°C accuracy from -10°C to +85°C and ±0.15°C accuracy at from 0°C to 35°C
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 6x single-ended or 3x differential freely programmable analog or digital IN & OUT • 8x pulse counting terminals with 2x control terminals • 7x configurable digital I/O terminals • 1x switched 12V OUT; 1x voltage excitation terminals • 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional), Wi-Fi (optional) • 30MB serial flash memory • Integral surge and ESD protection • Integrated 12 V battery solar charge regulator to charge batteries • Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols • Standard operating range of data logger -40° … +70°C • Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications • Soil moisture hygrometer to measure and monitor water content in soil (5% … 95%), operating temperature range from -65°C … 150°C • Waterproof digital temperature sensor to measure temperature of many liquids and gases at an operating temperature range from -55°C … 125°C, ±0.5°C accuracy from -10°C to +85°C and ±0.15°C accuracy at from 0°C to 35°C
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 4x multi-purpose analog input terminals: analog functions, digital I/O functions • 2x pulse counting programmable terminals • 2x configurable control digital I/O terminals • 2x switched 12V OUT; 2x voltage excitation terminals • 1x RS232, 1x RS-485, 1x USB Type C 2.0 • 50MB serial flash memory • Integral surge and ESD protection • Integrated 12 V battery solar charge regulator to charge batteries • Connect with PakBus, Modbus, DNP3, SDI-12, and other standard communication protocols • Standard operating range of data logger -40° … +70°C • Soil moisture hygrometer to measure and monitor water content in soil (5% … 95%), operating temperature range from -65°C … 150°C • Waterproof digital temperature sensor to measure temperature of many liquids and gases at an operating temperature range from -55°C … 125°C, ±0.5°C accuracy from -10°C to +85°C and ±0.15°C accuracy at from 0°C to 35°C
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT • RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available • 2/4 Mbytes SRAM memory (optionally extendable) • Surge protection for all Inputs by gas discharge tube (GDT) • Soil moisture hygrometer to measure and monitor water content in soil (5% … 95%), operating temperature range from -65°C … 150°C • Waterproof digital temperature sensor to measure temperature of many liquids and gases at an operating temperature range from -55°C … 125°C, ±0.5°C accuracy from -10°C to +85°C and ±0.15°C accuracy at from 0°C to 35°C
• Once powered up, the measurement automatically starts • 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT • RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available • 2/4 Mbytes SRAM memory (optionally extendable) • Keypad and LCD Display • Surge protection for all Inputs by gas discharge tube (GDT) • Standard operating range of data logger -25° … +50°C (optionally extended: -30° … +80°C) • Soil moisture hygrometer to measure and monitor water content in soil (5% … 95%), operating temperature range from -65°C … 150°C • Waterproof digital temperature sensor to measure temperature of many liquids and gases at an operating temperature range from -55°C … 125°C, ±0.5°C accuracy from -10°C to +85°C and ±0.15°C accuracy at from 0°C to 35°C
{{.}}
{{{.}}}