Aktueller Filter
• 4.3151.10.001 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Digital output protocoll: 16 bit serial synchronous • Digital output: 10 bit Gray Code • Without north gap • Accuracy: 0.75° • Resolution: 0.35° • W/o heating
• 4.3151.00.001 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Digital output protocoll: 16 bit serial synchronous • Digital output: 10 bit Gray Code • Without north gap • Accuracy: 0.75° • Resolution: 0.35° • With heating (25W)
• 4.3151.10.901 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Digital output protocoll: 16 bit serial synchronous • Digital output: 10 bit Gray Code • Without north gap • Accuracy: 0.75° • Resolution: 0.35° • W/o heating
• 4.3151.00.901 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Digital output protocoll: 16 bit serial synchronous • Digital output: 10 bit Gray Code • Without north gap • Accuracy: 0.75° • Resolution: 0.35° • With heating (25W)
• 4.3151.10.312 • Potentiometer 0 … 2.0 kOhm • Measurement range: 0...360° • Dead zone typ. 1.5° • Accuracy: ± 1.5° • Linearity: 0.35% (± 1.25°) • W/o heating
• 4.3151.00.312 • Potentiometer 0 … 2.0 kOhm • Measurement range: 0...360° • Dead zone typ. 1.5° • Accuracy: ± 1.5° • Linearity: 0.35% (± 1.25°) • With heating (24V AC/DC, 25W)
• 4.3151.10.020 - TMR • Potentiometer Simulator • Measurement range: 0...360° • Accuracy: 0.25% (1°) • Resolution: 0.35° • Power Supply: 3.3 ... 12 V DC • W/o heating
• 4.3151.00.020 - TMR • Potentiometer Simulator • Measurement range: 0...360° • Accuracy: 0.25% (1°) • Resolution: 0.35° • Power Supply: 3.3 ... 12 V DC • With heating (24V AC / DC, 25W)
• 4.3151.10.140 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 20 mA • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • W/o heating
• 4.3151.00.140 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 20 mA • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • With heating (24V AC / DC, 25W)
• 4.3151.10.141 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 4 ... 20 mA • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • W/o heating
• 4.3151.00.141 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 4 ... 20 mA • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • With heating (24V AC / DC, 25W)
• 4.3151.10.161 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 10 V • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • W/o heating
• 4.3151.00.161 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 10 V • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • With heating (24V AC / DC, 25W)
• 4.3151.10.173 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 5 V • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • W/o heating
• 4.3151.00.173 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 5 V • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • With heating (24V AC / DC, 25W)
• 4.3151.10.400 • Digital output, 8 bit (RS 485) • Measurement range: 0...360° • Option for connecting an anemometer „First Class 4.3351.x0.000“ (daisy chain) • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.1° • W/o heating
• 4.3151.00.400 • Digital output, 8 bit (RS 485) • Measurement range: 0...360° • Option for connecting an anemometer „First Class 4.3351.x0.000“ (daisy chain) • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.1° • With heating (24V AC / DC, 25W)
• Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
• LiYCY (TP) BK • Manufactured with special PVC-based compound insulation and cores twisted to pairs • Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
• Fits to Thies First Class sensors (anemometer and wind vanes) • Galvanic separation of sensor from boom & met mast structure • Durable POM thermoplastic • UV resistant
Service includes: • Inspection • Inspection report Subsequent to an inspection, the Client can decide if the sensor shall receive a Certified Maintenance and Refurbishment Service or, if needed, repair.
• Adapter is aligned to north by means of a bearing tube • A pin in the adapter and a north boring in the base of the wind direction sensor guarantee that the sensor is aligned to north • No realignment necessary with replacement of the sensor • Fixing boring for mast and sensor of 35mm diameter • Aluminum
For Thies and Vector Instruments (Windspeed Ltd.) wind vanes:For Thies and Vector Instruments (Windspeed Ltd.) anemometer: • Certified Maintenance (OEM TIER3 authorization) • Certified refurbishment (OEM TIER3 authorization) • Exchange of bearings, O-rings, sealings • Sensor Specific Report Certificate • Authorisation seal
For Thies and Vector Instruments (Windspeed Ltd.) wind vanes: • Repair (costs are sensor specific and depend on malfunction found) • Certificate • Authorization seal Scope & costs for repair depend on the individual sensor defects & conditions. A sensor specific offer will be made based upon inspection.
For all Thies First Class sensors anemometer and wind vanes • OEM recommended in order to maintain warranty
{{.}}
{{{.}}}