Low intensity Obstruction Lights

Obelux LI-200-DCW-A
• 1x signal light, type Obelux LI-200-DCW-A, intensity 200 cd
• Specifications met: CAP 168 Civil Aviation Authority, London, UK February 2001, Flight obstacle (low intensity) 
• Integrated photocell, user selectable sensitivity: off (default), 400 lux, 800 lux, 1600 lux
• With ​​​fault monitoring
• Operating Voltage: 10 - 60 VDC
• Power Consumption: 10 W

from 1,118.40 USD
Kintech Amplifier for Solar Radiation Sensors (mV)
TOP

Following sensors are supported:
• Hukseflux:    SR20-T1 / SRA20-T1, SR15-A1 / SRA15-A1, SR05-A1, SR11 / SR11 + AMF02, SR12, LP02
• Kipp & Zonen: CMP3, CMP6 / CMA6, CMP10, CMP11 / CMA11, CMP21 / CMP11 + CMF1, CMP22 / CMP22 + CMF1
• EKO: MS80, MS60, MS40, MS802
• LICOR: LI-200SZ

Price on request
Kintech PV Module Isc/Voc Sensor 2060
TOP

• Compatible with Orbit 360 Premium Data Logger
• Adds 6 more frequency channels to the Orbit 360 Premium
• Each channel can be configured individually
• Excellent noise and interface protectionT
• Resolution: 16 bits
• IEC-61400.12.1 approved sampling rate of 1Hz

Price on request
Hukseflux SR20-T2 Thermopile Pyranometer (calibrated)

• ISO 9060: Secondary Standard
• Measurement range: 0 W/m² to 4000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet (traceable to WRR)
• For Global Horizontal Irradiance (GHI) measurements (W/m2) 
• Sunshine duration (optional)
• With 10 kOhm thermistor
• With heating

Price on request
Hukseflux SR05-D2A2 Pyranometer (calibrated)

• ISO 9060: Class C
• Measurement range: 0 to 2000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet with each sensor; traceable to World Radiometric Reference (WRR)
• Response time: 18 s
• Communication:
    Analog: 4 to 20 mA
    Digital: Modbus RS-485

Price on request
Hukseflux SR05-D1A3 Pyranometer (calibrated)

• ISO 9060: Class C
• Measurement range: 0 to 2000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet with each sensor; traceable to World Radiometric Reference (WRR)
• Response time: 18 s
• Communication:
    Analog: 0 to 1 V
    Digital: Modbus RS-485

Price on request
Hukseflux SR15-D2A2 Pyranometer (calibrated)

• ISO 9060: Class B
• Measurement range: 0 to 3000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet with each sensor; traceable to World Radiometric Reference (WRR)
• Communication:
    Analog: 4-20 mA
    Digital: Modbus RS-485
• Power Consumption: < 0.048 W at 12 VDC (unheated)

Price on request