• Temperature: Measurement range: -40 ... 85 °C Accuracy (-40 … 85 °C, moved air > 2 m/s): ±0.1 °C • Relative Humidity: Measurement range: 0 ... 100 % rH Accuracy: 1.5 % rH • Pressure: Measurement range: 300 ... 1200 hPa Accuracy (@ -20 … 80°C @ 800...1100 hPa): ±0.25 hPa • Supply Voltage: 6 ... 30 V DC • Output: RS485, Half-duplex 8N1 (Baud rate configurable), Thies ASCII
• Temperature: Measurement range: -40 ... 85 °C Accuracy (-40 … 85 °C, moved air > 2 m/s): ±0.1 °C • Relative Humidity: Measurement range: 0 ... 100 % rH Accuracy: 1.5 % rH • Pressure: Measurement range: 300 ... 1200 hPa Accuracy (@ -20 … 80°C @ 800...1100 hPa): ±0.25 hPa • Supply Voltage: 6 ... 30 V DC • Output: RS485, Half-duplex 8N1 (Baud rate configurable), Modbus RTU
• Supply Voltage: 5 ... 45 VDC • Power Consumption (at 12 V): < 1mA (standby 40 μA) • Range: 600 ... 1100 hPa • Accuracy: ±0.2 hPa (600 ... 1100 hPa, –40 ... 85 °C) • Resolution: 1/64 hPa ≈ 0.0156 hPa • Output Voltage: 0 ... 2.5 or 0 ... 5 VDC • Long-Term Drift: ±0.05 ... 0.06 hPa
• Temperature: Range: -40 ... 80 °C Accuracy: ±0.1 °C • Humidity: Range: 0 ... 100% rH Accuracy: ±1% rH • Interfaces: RS-485, SDI-12, USB • Input Voltage: 5 ... 45 VDC, (Peak up to 60 VDC) • Power Consumption (normal, always on) at 12 VDC: 14 µA, 0.6 mA • Dimensions: Ø20 mm x 130 mm
• Temperature: Range: -40 ... 80 °C Accuracy: ±0.1 °C • Humidity: Range: 0 ... 100% rH Accuracy: ±1% rH • Pressure: Range: 400 ...1200 hPa Accuracy (400 ... 1100 hPa, –40 ... 85 °C): ±0.4 hPa • Linearity Compensation: 32 points • Interfaces: RS-485, SDI-12, USB • IP 65 • Input Voltage: 5 ... 45 VDC
• Three fully integrated sensing elements operate in parallel. Their data is internally processed, cross-checked and averaged. • Temperature: Range: -40 ... 80 °C Resolution: 0.01 °C Accuracy: ±0.1 °C • Humidity: Range: 0 ... 100% rH Resolution: 0.01% rH Accuracy: ±1% rH • Interfaces: RS-485, RS-232, SDI-12, USB • Calibrated
• Supply Voltage: 5 ... 45 VDC • Power Consumption: 20 μA (12 V, normal use), 3 μA (12 V, always on) • Range: 400 ... 1200 hPa • Accuracy: ±0.2 hPa (400 ... 1100 hPa, –40 ... 85 °C) • Resolution: 1/64 hPa ≈ 0.0156 hPa • Interfaces: RS-485, RS-232, SDI-12, USB • Protocols: Modbus RTU/ASCII, SDI-12, USB-CDC
{{.}}
{{{.}}}