Suche
• 4.3151.00.001 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Digital output protocoll: 16 bit serial synchronous • Digital output: 10 bit Gray Code • Without north gap • Accuracy: 0.75° • Resolution: 0.35° • With heating (25W)
• 4.3151.10.001 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Digital output protocoll: 16 bit serial synchronous • Digital output: 10 bit Gray Code • Without north gap • Accuracy: 0.75° • Resolution: 0.35° • W/o heating
• 5.4106.00.100 • Precipitation (yes/no) • 18 cm2 sensor area • Semiconductor relay, Potential-free / electrically isolated / metallically separated • Sensitivity: approx. 0.2 mm/h • Operating voltage: 11...28VAC or 11...32VDC (max. 0.75A)
• 4.3129.10.712 • Potentiometer 0 … 2.0 kOhm • Measurement range: 0...360° • Without north gap • Resolution: 0.5° • Accuracy: 0.5% (±2°) • W/o heating
• 4.3351.10.000 - unheated • Frequency output (1082 Hz at 50 m/s) • Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2 • Supply 3.3 ... 42 V DC • Measurement Range: 0.3...75 m/s • Accuracy: 1% of value or <0.2 m/s (0.3...50m/s) • Linearity: r>0.99999 (4...20 m/s) • W/o heating
• 4.3151.00.901 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Digital output protocoll: 16 bit serial synchronous • Digital output: 10 bit Gray Code • Without north gap • Accuracy: 0.75° • Resolution: 0.35° • With heating (25W)
• 4.3151.10.901 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Digital output protocoll: 16 bit serial synchronous • Digital output: 10 bit Gray Code • Without north gap • Accuracy: 0.75° • Resolution: 0.35° • W/o heating
Thies Clima Sensor US - 4.9200.20.000 • Additional ceramic precipitation sensor for more precise detection of precipitation and the measurement of global radiation • Wind speed: 0.01 ... 60 m/s • Wind direction: 0 ... 360° • Pressure: 500 ... 1200 hPa • Temperature: -40 ... +80 °C • Relative Humditiy: 0 ... 100 %RH • Brightness: 1 lux... 150 klux • Precipitation: Intensities 0.001 ... 999mm/h • Heating (optional) at 24 V AC/DC • Operating voltage: 6 ... 40 VDC or 10 ... 28 VAC • Data output digital: RS485 / RS422 and analogue: 0 ... 10V
Thies Clima Sensor US - 4.9200.00.000 • Wind speed: 0.01 ... 60 m/s • Wind direction: 0 ... 360° • Pressure: 500 ... 1200 hPa • Temperature: -40 ... +80 °C • Relative Humditiy: 0 ... 100 %RH • Brightness: 1 lux... 150 klux • Precipitation: Intensities 0.001 ... 999mm/h • Heating (optional) at 24 V AC/DC • Operating voltage: 6 ... 40 VDC or 10 ... 28 VAC • Data output digital: RS485 / RS422 and analogue: 0 ... 10V
• 5.4103.10.700 • Precipitation (rain, snow, hail, etc.) • 25 cm2 sensor area • Signal output: Precipitation = relay OFF; no precipitation = relay ON • Operating voltage: 24V AC/DC
• 4.3151.10.312 • Potentiometer 0 … 2.0 kOhm • Measurement range: 0...360° • Dead zone typ. 1.5° • Accuracy: ± 1.5° • Linearity: 0.35% (± 1.25°) • W/o heating
• 4.3151.00.312 • Potentiometer 0 … 2.0 kOhm • Measurement range: 0...360° • Dead zone typ. 1.5° • Accuracy: ± 1.5° • Linearity: 0.35% (± 1.25°) • With heating (24V AC/DC, 25W)
• 3.1157.10.000 • 0...5V output, set 800...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.040 • 0...20mA output, set 600...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.041 • 4...20mA output, set 600...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
Thies Clima Sensor US - 4.9201.00.000 • Wind speed: 0.01 ... 60 m/s • Wind direction: 0 ... 360° • Pressure: 500 ... 1200 hPa • Temperature: -40 ... +80 °C • Relative Humditiy: 0 ... 100 %RH • Heating (optional) at 24 V AC/DC • Operating voltage: 6 ... 40 VDC or 10 ... 28 VAC • Data output digital: RS485 / RS422 and analogue: 0 ... 10V
• 3.1157.10.141 • 4...20mA output, set 800...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.140 • 0...20mA output, set 800...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 4.3151.00.020 - TMR • Potentiometer Simulator • Measurement range: 0...360° • Accuracy: 0.25% (1°) • Resolution: 0.35° • Power Supply: 3.3 ... 12 V DC • With heating (24V AC / DC, 25W)
• 4.3151.10.020 - TMR • Potentiometer Simulator • Measurement range: 0...360° • Accuracy: 0.25% (1°) • Resolution: 0.35° • Power Supply: 3.3 ... 12 V DC • W/o heating
• 4.3129.00.712 • Potentiometer 0 … 2.0 kOhm • Measurement range: 0...360° • Without north gap • Resolution: 0.5° • Accuracy: 0.5% (±2°) • With heating (24V AC / DC, 20W)
• 4.3351.00.000 - heated • Frequency output (1082 Hz at 50 m/s) • Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2 • Supply 3.3 ... 42 V DC • Measurement Range: 0.3...75 m/s • Accuracy: 1% of value or <0.2 m/s (0.3...50m/s) • Linearity: r>0.99999 (4...20 m/s) • With heating (24V AC/DC, 25W)
• 4.3820.00.000 • Measurement variables possible (2 dimensions): • Horizontal components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° (0...540°, 0...720° analogue adjustable) • Virtual temperature measurement range: - 50°C ... +70°C • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Maintenance free • Digital /analogue in- and outputs
• 4.3352.10.000 - unbeheizt • Frequency output (1082 Hz at 50 m/s) • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • Supply 3.3 ... 48 V DC • Measurement Range: 0.3...75 m/s • Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s) • Linearity: r>0.99999 (4...20 m/s)
• 4.3129.70.701 • Measurement range: 0...360° • Dead band: without north gap • Measurement principle: magnetic • Output: 10 bit serial-synchronous Gray-code • Resolution: 0.35° • Accuracy: ±1.5° • W/o heating • Power Supply: 3.3 ... 30 V DC or 24 V AC
• 4.3875.20.381 • Standard Heating Stainless-steel caps • With optionally integrated Baro-transmitter • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3877.07.000 • Standard Heating Stainless-steel caps • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3877.27.000 • Standard Heating Stainless-steel caps • With optionally integrated Baro-transmitter • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3875.20.340 • Standard Heating Stainless-steel caps • With optionally integrated Baro-transmitter • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3875.60.340 • Reinforced heating with 48 VDC • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics 12 VDC • Maintenance free
Thies Clima Sensor US - 4.9202.00.000 • Wind speed: 0.01 ... 60 m/s • Wind direction: 0 ... 360° • Brightness: 1 lux... 150 klux • Precipitation: Intensities 0.001 ... 999mm/h • Heating (optional) at 24 V AC/DC • Operating voltage: 6 ... 40 VDC or 10 ... 28 VAC • Data output digital: RS485 / RS422 and analogue: 0 ... 10V
• 4.3875.00.340 • Standard Heating Stainless-steel caps • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3875.00.260 • Standard Heating Stainless-steel caps • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Interface Configuration with Baud rate of 4800/N81 and NMEA Telegram • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3820.42.503 • PTC Heating Stainless-steel caps and additional chassis heating • Measurement variables possible (2 dimensions): • Horizontal components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° (0...540°, 0...720° analogue adjustable) • Virtual temperature measurement range: - 50°C ... +70°C • Half Duplex Interface Configuration with Baud rate of 38400/N81 • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 48V AC/DC • Maintenance free
• 4.3820.32.503 • Measurement variables possible (2 dimensions): • Horizontal components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° (0...540°, 0...720° analogue adjustable) • Virtual temperature measurement range: - 50°C ... +70°C • Half Duplex Interface Configuration with Baud rate of 38400/N81 • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Maintenance free
Thies Clima Sensor US - 4.9203.00.000 • Wind speed: 0.01 ... 60 m/s • Wind direction: 0 ... 360° • Heating (optional) at 24 V AC/DC • Operating voltage: 6 ... 40 VDC or 10 ... 28 VAC • Data output digital: RS485 / RS422 and analogue: 0 ... 10V
• 4.3352.00.000 - beheizt • Frequency output (1082 Hz at 50 m/s) • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • With heating (24V AC/DC, 25W) • Supply 3.3 ... 48 V DC • Measurement Range: 0.3...75 m/s • Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s) • Linearity: r>0.99999 (4...20 m/s)
• 4.3129.60.701 • Measurement range: 0...360° • Dead band: without north gap • Measurement principle: magnetic • Output: 10 bit serial-synchronous Gray-code • Resolution: 0.35° • Accuracy: ±1.5° • With heating (24V AC / DC, 20W) • Power Supply: 3.3 ... 30 V DC or 24 V AC
• 4.3352.10.400 - unbeheizt • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • W/o heating • Measurement Range: 0.3...75 m/s • Outputs: RS485 / ASCII / MODBUS • Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain) • Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
• 4.3129.70.773 • Measurement range: 0...360° • Dead band: without north gap • Measurement principle: magnetic • Output: 0 to 5 V • Resolution: 0.4° • Accuracy: ±2° • W/o heating • Power Supply: 8 ... 30 V DC or 24 V AC
• 4.3830.42.503 • PTC Heating Stainless-steel caps and additional chassis heating • Measurement variables possible (3 dimensions): • Horizontal and vertical components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 85 m/s] • Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90° • Virtual temperature measurement range: - 40°C ... +70°C • Sample rate: 0.1 Hz ... 100 Hz • Half Duplex Interface Configuration with Baud rate of 38400/N81 • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 48V AC/DC • Maintenance free
• 4.3830.22.503 • Measurement variables possible (3 dimensions): • Horizontal and vertical components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 85 m/s] • Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90° • Virtual temperature measurement range: - 40°C ... +70°C • Sample rate: 0.1 Hz ... 100 Hz • Half Duplex Interface Configuration with Baud rate of 38400/N81 • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Maintenance free
• 4.3129.60.773 • Measurement range: 0...360° • Dead band: without north gap • Measurement principle: magnetic • Output: 0 to 5 V • Resolution: 0.4° • Accuracy: ±2° • With heating (24V AC / DC, 20W) • Power Supply: 8 ... 30 V DC or 24 V AC
• 4.3352.00.400 - beheizt • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • With heating (24V AC/DC, 25W) • Measurement Range: 0.3...75 m/s • Outputs: RS485 / ASCII / MODBUS • Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain) • Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
• 4.3830.20.340 • Measurement variables possible (3 dimensions): • Horizontal and vertical components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 85 m/s] • Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90° • Virtual temperature measurement range: - 40°C ... +70°C • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Maintenance free • Digital /analogue in- and outputs
• 4.3352.10.401 - unbeheizt • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • W/o heating • Measurement Range: 0.3...75 m/s • Outputs: RS485 / ASCII / MODBUS • Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain) • Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
• 4.3129.00.761 • Electrical Output: 0 … 10 V • Measurement range: 0...360° • Without north gap • Measurement principle: opto-electronic • Resolution: 11.25° (5 bit Gray code, 32 sectors) • Accuracy: ±5° • With heating (24V AC / DC, 20W) • Power Supply: 15 ... 30 V DC or 24 V AC
• 4.3352.00.401 - beheizt • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • With heating (24V AC/DC, 25W) • Measurement Range: 0.3...75 m/s • Outputs: RS485 / ASCII / MODBUS • Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain) • Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
• 4.3129.00.740 • Electrical Output: 0 … 20 mA • Measurement range: 0...360° • Without north gap • Measurement principle: opto-electronic • Resolution: 11.25° (5 bit Gray code, 32 sectors) • Accuracy: ±5° • With heating (24V AC / DC, 20W) • Power Supply: 15 ... 30 V DC or 24 V AC
• 4.3151.10.140 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 20 mA • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • W/o heating
• 4.3351.10.140 • Frequency output (1082 Hz at 50 m/s) • Analogue output (0 ... 20 mA = 0.3...75 m/s) • Supply 15 ... 24 V DC • W/o heating
• 4.3129.80.000 • Measurement range: 0...360° • Dead band: without north gap • Measurement principle: magnetic • With heating (24V AC / DC, 60W) • Power Supply: 8 ... 30 V DC or 24 V AC, model dependent
• Measurement range T: -40... +85°C • Measurement range rH: 0...100 %rH • Measurement range P: 300...1200 hPa • Electrical output: 0...1V; 0...10V; 4...20mA • Serial output: RS485, Half-duplex 8N1 (Baud rate configurable)
• 507245 • Consisting of 1x wire and 2x clip • Suitable for Thies Ultrasonic Anemometer 1D and 2D
• 508396 • Consisting of 1x spike and protective cap • Suitable for Thies Ultrasonic Anemometer 1D, 2D, and 3D
• 4.3151.00.140 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 20 mA • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • With heating (24V AC / DC, 25W)
• 4.3351.00.140 • Frequency output (1082 Hz at 50 m/s) • Analogue output (0 ... 20 mA = 0.3...75 m/s) • Supply 15 ... 24 V DC • Heated
• 4.3151.10.141 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 4 ... 20 mA • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • W/o heating
• 4.3351.10.141 • Frequency output (1082 Hz at 50 m/s) • Analogue output (4 ... 20 mA = 0.3...75 m/s) • Supply 15 ... 24 V DC • W/o heating
• 4.3151.00.141 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 4 ... 20 mA • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • With heating (24V AC / DC, 25W)
• 4.3351.00.141 • Frequency output (1082 Hz at 50 m/s) • Analogue output (4 ... 20 mA = 0.3...75 m/s) • Supply 15 ... 24 V DC • Heated
• 4.3151.10.161 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 10 V • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • W/o heating
• 4.3351.10.161 • Frequency output (1082 Hz at 50 m/s) • Analogue output (0 ... 10 V = 0.3...75 m/s) • Supply 15 ... 24 V DC • W/o heating
• 4.3151.00.161 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 10 V • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • With heating (24V AC / DC, 25W)
• 4.3351.00.161 • Frequency output (1082 Hz at 50 m/s) • Analogue output (0 ... 10 V = 0.3...75 m/s) • Supply 15 ... 24 V DC • Heated
• 4.3151.10.173 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 5 V • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • W/o heating
• 4.3865.01.310 • Measurement variables possible (1 dimension): • Horizontal components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0 ... 75 m/s] • Wind direction measurement range: 0° (1°) / 180° (181°) and "calm" • Virtual temperature measurement range: - 50°C ... +70°C • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Maintenance free • Digital /analogue in- and outputs
• 4.3151.00.173 • TMR-Sensor (Tunnel Magneto Resistance) • Measurement range: 0...360° • Electrical output 0 ... 5 V • Resolution analogue = 10 bit • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.35° • With heating (24V AC / DC, 25W)
• 4.3151.10.400 • Digital output, 8 bit (RS 485) • Measurement range: 0...360° • Option for connecting an anemometer „First Class 4.3351.x0.000“ (daisy chain) • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.1° • W/o heating
• 4.3520.10.000 • Measurement Range: 0.5...50 m/s • Accuracy: ± 0.5 m/s or 3% of measuremet value • Resolution: 0.1 m/s • Frequency output (2 - 573 Hz) • Supply 15 ... 28 V DC • W/o heating • Opto-electronic principle
• 4.3151.00.400 • Digital output, 8 bit (RS 485) • Measurement range: 0...360° • Option for connecting an anemometer „First Class 4.3351.x0.000“ (daisy chain) • Without north gap • Accuracy: 0.25% (1°) • Resolution: 0.1° • With heating (24V AC / DC, 25W)
• 4.3520.00.000 • Measurement Range: 0.5...50 m/s • Accuracy: ± 0.5 m/s or 3% of measuremet value • Resolution: 0.1 m/s • Frequency output (2 - 573 Hz) • Supply 15 ... 28 V DC • With heating • Opto-electronic principle
For all Thies First Class sensors anemometer and wind vanes • OEM recommended in order to maintain warranty
{{.}}
{{{.}}}