Suche
• Three fully integrated sensing elements operate in parallel. Their data is internally processed, cross-checked and averaged. • Temperature: Range: -40 ... 80 °C Resolution: 0.01 °C Accuracy: ±0.1 °C • Humidity: Range: 0 ... 100% rH Resolution: 0.01% rH Accuracy: ±1% rH • Interfaces: RS-485, RS-232, SDI-12, USB • Calibrated
• Temperature: Range: -40 ... 80 °C Accuracy: ±0.1 °C • Humidity: Range: 0 ... 100% rH Accuracy: ±1% rH • Pressure: Range: 400 ...1200 hPa Accuracy (400 ... 1100 hPa, –40 ... 85 °C): ±0.4 hPa • Linearity Compensation: 32 points • Interfaces: RS-485, SDI-12, USB • IP 65 • Input Voltage: 5 ... 45 VDC
• Supply Voltage: 5 ... 45 VDC • Power Consumption: 20 μA (12 V, normal use), 3 μA (12 V, always on) • Range: 400 ... 1200 hPa • Accuracy: ±0.2 hPa (400 ... 1100 hPa, –40 ... 85 °C) • Resolution: 1/64 hPa ≈ 0.0156 hPa • Interfaces: RS-485, RS-232, SDI-12, USB • Protocols: Modbus RTU/ASCII, SDI-12, USB-CDC
{{.}}
{{{.}}}