New product

Thies Clima Sensor US

Thies Clima Sensor US - 4.9202.00.000
• Wind speed: 0.01 ... 60 m/s
• Wind direction: 0 ... 360°
• Brightness: 1 lux... 150 klux
• Precipitation: Intensities 0.001 ... 999mm/h
• Heating (optional) at 24 V AC/DC
• Operating voltage: 6 ... 40 VDC or 10 ... 28 VAC
• Data output digital: RS485 / RS422 and analogue: 0 ... 10V

 

from 2,278.80 USD
Thies Clima Sensor US

Thies Clima Sensor US - 4.9201.00.000
• Wind speed: 0.01 ... 60 m/s
• Wind direction: 0 ... 360°
• Pressure: 500 ... 1200 hPa
• Temperature: -40 ... +80 °C
• Relative Humditiy: 0 ... 100 %RH
• Heating (optional) at 24 V AC/DC
• Operating voltage: 6 ... 40 VDC or 10 ... 28 VAC
• Data output digital: RS485 / RS422 and analogue: 0 ... 10V

 

from 2,040.12 USD
Thies Clima Sensor US

Thies Clima Sensor US - 4.9200.00.000
• Wind speed: 0.01 ... 60 m/s
• Wind direction: 0 ... 360°
• Pressure: 500 ... 1200 hPa
• Temperature: -40 ... +80 °C
• Relative Humditiy: 0 ... 100 %RH
• Brightness: 1 lux... 150 klux

• Precipitation: Intensities 0.001 ... 999mm/h
• Heating (optional) at 24 V AC/DC
• Operating voltage: 6 ... 40 VDC or 10 ... 28 VAC
• Data output digital: RS485 / RS422 and analogue: 0 ... 10V

from 2,417.04 USD
Ultrasonic Anemometer Thies 2D Compact

4.3875.00.340
• Standard Heating Stainless-steel caps 
• Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360°
• Virtual temperature measurement range: - 50°C ... +70°C
• Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2)
• Output range: 10 per 1 sec
 
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics and heating of 12 VDC
• Maintenance free

from 2,152.98 USD
Ultrasonic Anemometer Thies 2D Compact

4.3875.00.260
• Standard Heating Stainless-steel caps 
• Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360°
• Virtual temperature measurement range: - 50°C ... +70°C
• Full Duplex Interface Configuration with Baud rate of 4800/N81 and NMEA Telegram
 
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Supply of electronics and heating of 12 VDC
• Maintenance free

from 2,154.60 USD
Thies First Class Wind Vane - heated

4.3151.00.312
• Potentiometer 0 … 2.0 kOhm 
• Measurement range: 0...360°
• Dead zone typ. 1.5°
• Accuracy: ± 1.5°
• Linearity: 0.35% (± 1.25°)
• With heating (24V AC/DC, 25W)

from 1,192.32 USD
Thies First Class Wind Vane

4.3151.10.312
• Potentiometer 0 … 2.0 kOhm 
• Measurement range: 0...360°
• Dead zone typ. 1.5°
• Accuracy: ± 1.5°
• Linearity: 0.35% (± 1.25°)
• W/o heating

from 1,149.12 USD