Suche
• Biasing and termination of RS485-Bus
• NRG S1 Anemometer (MEASNET Calibrated) • Frequency output 0 Hz to 800 Hz • Supply 5 ... 28 VDC • Measurement Range: 0.6...75 m/s • Resolution: 0.046 m/s • Operating temperature range: -50 °C … 80 °C • W/o heating
• 4.3877.27.000 • Standard Heating Stainless-steel caps • With optionally integrated Baro-transmitter • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3877.07.000 • Standard Heating Stainless-steel caps • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3875.20.381 • Standard Heating Stainless-steel caps • With optionally integrated Baro-transmitter • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• High sensitivity dust sensor • Measurable particulates: PM1/ PM2.5 / PM10 • Cost effectiveness, trouble-free installation, deployment, and maintenance • Supply: 5VDC, 12-24 VDC • Output: RS485 • Accuracy: ±3%FS @25℃ • Operating temperature: -20℃ to +50℃ @15-80%RH
• High sensitivity dust sensor • Measurable particulates: PM2.5 / PM10 • Cost effectiveness, trouble-free installation, deployment, and maintenance • Supply: 5VDC, 12-24 VDC • Output: 4-20mA, 0-5V, 0-10V • Accuracy: ±3%FS @25℃ • Operating temperature: -20℃ to +50℃ @15-80%RH
{{.}}
{{{.}}}