Suche
• USB (2.0) interface with up to 2GB flash storage • Allows Plug&Play field upgrades and configuration by using our Device Configuration utility • Expands data logger storage by 2 GB, tandem operation with Compact Flash card possible • Shuttles data, OS, and program files between Campbell Scientific dataloggers and a PC • For CR800, CR850, CR1000, CR6, CR3000, CR5000, CR9000(X)
• An all-digital measurement and control DAQ • 24-bit ADC • 12x individually configured inputs for analog or digital functions • 16x terminals configurable for digital I/O • Built-in Wi-Fi and USB Micro-B for computer connectivity • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• One of the most computationally powerful data-acquisition devices from Campbell Scientific • 24 bit and 32 bit ADC • An all-digital measurement and control DAQ • 8x digital I/O terminals (configurable) • 2x switched 12V • EPI port switch for high-speed connection to all GRANITE modules • Built-in GPS for network synchronization • Built-in Wi-Fi • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• One of the most computationally powerful data-acquisition devices from Campbell Scientific • 24 bit and 32 bit ADC • An all-digital measurement and control DAQ • 8x digital I/O terminals (configurable) • 4 General-purpose CAN channels • 2x switched 12V • EPI port switch for high-speed connection to all GRANITE modules • Built-in GPS for network synchronization • Built-in Wi-Fi • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• General-purpose, multiplexed analog measurement module • 8 differential or 16 single-ended input channels with 2 excitation channels • 1x switched 12V and 2x switched 5V • Channel count expansion via the CPI bus • USB 2.0 interface for direct-to-PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• General-purpose, multiplexed analog measurement module • 16 differential or 32 single-ended input channels with 2 excitation channels • 2x switched 12V and 4x switched 5V • Channel count expansion via the CPI bus • USB 2.0 interface for direct-to-PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Purpose-built thermocouple measurement module • Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers • 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors • Resolution of 0.015°C • Handles extreme temperature environments and rapid thermal gradients • Time base can be referenced either to GPS or a temperature-compensated real-time clock • CPI DAQ connection for channel expansion • USB 2.0 interface for PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
{{.}}
{{{.}}}