Search
• 4.3352.10.401 - unheated • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • W/o heating • Measurement Range: 0.3...75 m/s • Outputs: RS485 / ASCII / MODBUS • Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain) • Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
• 4.3352.10.400 - unheated • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • W/o heating • Measurement Range: 0.3...75 m/s • Outputs: RS485 / ASCII / MODBUS • Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain) • Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
• 4.3352.00.400 - heated • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • With heating (24V AC/DC, 25W) • Measurement Range: 0.3...75 m/s • Outputs: RS485 / ASCII / MODBUS • Option for connecting a bus-compatible wind vanes and anemometers in parallel (daisy chain) • Measures next to wind speed also: Air pressure: 300 ... 1100 hPa (Accuracy: ±1 hPa @ 20 °C) Indication: Measuring range: -89.9 ... +89.9° (Accuracy: ±1 °) Vibration: Measuring range: 0 ... 50 Hz (Accuracy: ±0.4 Hz) Acceleration: Measuring range: ±8 g (Accuracy: ±30 mg)
• 4.3352.00.000 - heated • Frequency output (1082 Hz at 50 m/s) • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • With heating (24V AC/DC, 25W) • Supply 3.3 ... 48 V DC • Measurement Range: 0.3...75 m/s • Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s) • Linearity: r>0.99999 (4...20 m/s)
• 4.3352.10.000 - unheated • Frequency output (1082 Hz at 50 m/s) • Class A compliant according to IEC 61400-12-1 & 61400-12-1 Ed.2 • Supply 3.3 ... 48 V DC • Measurement Range: 0.3...75 m/s • Accuracy: <1% of value or < ±0.2 m/s (0.3...50m/s) • Linearity: r>0.99999 (4...20 m/s)
• For 2D and 3D ultra sonic anemometer • Wind speed: at 2 azimuth positions (by default at 0° and 180°), each with 13 points at 13 wind speeds • Wind direction: over 380° (350° ... 10°) at 8 m/s • MEASNET wind tunnel calibration • Traceable according to DAkkS (ilac-MRA)
• Permanent structure • Without guy wires, self-supported • Lifetime expectancy: 50 years
{{.}}
{{{.}}}