Suche
• General-purpose, multiplexed analog measurement module • 8 differential or 16 single-ended input channels with 2 excitation channels • 1x switched 12V and 2x switched 5V • Channel count expansion via the CPI bus • USB 2.0 interface for direct-to-PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• One of the most computationally powerful data-acquisition devices from Campbell Scientific • 24 bit and 32 bit ADC • An all-digital measurement and control DAQ • 8x digital I/O terminals (configurable) • 4 General-purpose CAN channels • 2x switched 12V • EPI port switch for high-speed connection to all GRANITE modules • Built-in GPS for network synchronization • Built-in Wi-Fi • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• One of the most computationally powerful data-acquisition devices from Campbell Scientific • 24 bit and 32 bit ADC • An all-digital measurement and control DAQ • 8x digital I/O terminals (configurable) • 2x switched 12V • EPI port switch for high-speed connection to all GRANITE modules • Built-in GPS for network synchronization • Built-in Wi-Fi • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Measurement range T: -30...70 °C • Measurement range rH: 0...100 %rH • Fine-pored sintered filter made from high-grade steel, protects the sensor against high air speeds and dusty conditions • Factory calibration
• ISO 9060: Secondary Standard • Measurement range: -400 W/m² to 4000 W/m² • Spectral range: 285 to 3000 nm • Incl. calibration sheet (traceable to WRR) • For Global Horizontal Irradiance (GHI) measurements (W/m2) • Sunshine duration (optional)
• ISO 9060: Secondary Standard • Measurement range: 0 W/m² to 4000 W/m² • Spectral range: 285 to 3000 nm • Incl. calibration sheet (traceable to WRR) • For Global Horizontal Irradiance (GHI) measurements (W/m2) • Sunshine duration (optional) • With Pt100 (T1 version) or 10 kOhm thermistor (T2 version) • With heating
• Most accurate digital secondary standard pyranometer available • ISO 9060: Secondary Standard • Measurement range: 0 W/m² to 4000 W/m² • Spectral range: 285 to 3000 nm • Incl. calibration sheet (traceable to WRR) • For Global Horizontal Irradiance (GHI) measurements (W/m2) • Sunshine duration (optional)
{{.}}
{{{.}}}