• 4.3129.10.712 • Potentiometer 0 … 2.0 kOhm • Measurement range: 0...360° • Without north gap • Resolution: 0.5° • Accuracy: 0.5% (±2°) • W/o heating
• 4.3129.00.712 • Potentiometer 0 … 2.0 kOhm • Measurement range: 0...360° • Without north gap • Resolution: 0.5° • Accuracy: 0.5% (±2°) • With heating (24V AC / DC, 20W)
• 4.3129.70.701 • Measurement range: 0...360° • Dead band: without north gap • Measurement principle: magnetic • Output: 10 bit serial-synchronous Gray-code • Resolution: 0.35° • Accuracy: ±1.5° • W/o heating • Power Supply: 3.3 ... 30 V DC or 24 V AC
• 4.3129.60.701 • Measurement range: 0...360° • Dead band: without north gap • Measurement principle: magnetic • Output: 10 bit serial-synchronous Gray-code • Resolution: 0.35° • Accuracy: ±1.5° • With heating (24V AC / DC, 20W) • Power Supply: 3.3 ... 30 V DC or 24 V AC
• 4.3129.70.773 • Measurement range: 0...360° • Dead band: without north gap • Measurement principle: magnetic • Output: 0 to 5 V • Resolution: 0.4° • Accuracy: ±2° • W/o heating • Power Supply: 8 ... 30 V DC or 24 V AC
• 4.3129.60.773 • Measurement range: 0...360° • Dead band: without north gap • Measurement principle: magnetic • Output: 0 to 5 V • Resolution: 0.4° • Accuracy: ±2° • With heating (24V AC / DC, 20W) • Power Supply: 8 ... 30 V DC or 24 V AC
• 4.3129.00.761 • Electrical Output: 0 … 10 V • Measurement range: 0...360° • Without north gap • Measurement principle: opto-electronic • Resolution: 11.25° (5 bit Gray code, 32 sectors) • Accuracy: ±5° • With heating (24V AC / DC, 20W) • Power Supply: 15 ... 30 V DC or 24 V AC
• 4.3129.00.740 • Electrical Output: 0 … 20 mA • Measurement range: 0...360° • Without north gap • Measurement principle: opto-electronic • Resolution: 11.25° (5 bit Gray code, 32 sectors) • Accuracy: ±5° • With heating (24V AC / DC, 20W) • Power Supply: 15 ... 30 V DC or 24 V AC
• 4.3129.80.000 • Measurement range: 0...360° • Dead band: without north gap • Measurement principle: magnetic • With heating (24V AC / DC, 60W) • Power Supply: 8 ... 30 V DC or 24 V AC, model dependent
• Fits to Thies Compact sensors (anemometer and wind vanes) • Galvanic separation of sensor from boom & met mast structure • Durable POM thermoplastic • UV resistant
• Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
• LiYCY (TP) BK • Manufactured with special PVC-based compound insulation and cores twisted to pairs • Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
Service includes: • Inspection • Inspection report Subsequent to an inspection, the Client can decide if the sensor shall receive a Certified Maintenance and Refurbishment Service or, if needed, repair.
For Thies and Vector Instruments (Windspeed Ltd.) wind vanes: • Repair (costs are sensor specific and depend on malfunction found) • Certificate • Authorization seal Scope & costs for repair depend on the individual sensor defects & conditions. A sensor specific offer will be made based upon inspection.
{{.}}
{{{.}}}