• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 16x analogue single-ended or 8 differential Analog Inputs, 10x pulse counters, 8x digital IN/OUT (configurable), 4x analogue voltage (switched excitation mode or switched regulated voltage supply), 2x switched 12V • RS485/232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port, Wi-Fi (optional module) • 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB • Surge, Electrostatic Discharge and Lightning Protection for all critical Inputs and Outputs • Power in 9.6V to 36VDC • Stainless steel type-D connectors and gold plating improvements on RJ45s • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 16x analogue single-ended or 8 differential Analog Inputs, 10x pulse counters, 8x digital IN/OUT (configurable), 4x analogue voltage (switched excitation mode or switched regulated voltage supply), 2x switched 12V • RS232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port, Wi-Fi (optional module) • 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB • Surge, Electrostatic Discharge and Lightning Protection for all critical Inputs and Outputs • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 12x single-ended or 6x differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • LAN, USB, RJ-45, Micro-SD card • 4 Mbytes SRAM memory (extendable) • Surge protection for critical Outputs by GDT or transient voltage suppression diodes • Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 12x single-ended or 6x differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • LAN, USB, RJ-45, Micro-SD card • WLAN Wi-Fi for short-range wireless IP communications based on 802.11 b/g/n, WPA/WPA2-Personal, WPA/WPA2-Enterprise Security, WEP • 4 Mbytes SRAM memory (extendable) • Surge protection for critical Outputs by GDT or transient voltage suppression diodes • Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) • 12x single-ended or 6x differential freely programmable analog or digital IN & OUT • 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V) • 2x switched 12V OUT • 1x RS232 / RS485 • CS I/O PORT • LAN, USB, RJ-45, Micro-SD card • Internal RF422 modem (or optional for specific countries: RF407, RF412, RF451) • 4 Mbytes SRAM memory (extendable) • Surge protection for critical Outputs by GDT or transient voltage suppression diodes • Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 6x single-ended or 3x differential freely programmable analog or digital IN & OUT • 8x pulse counting terminals with 2x control terminals • 7x configurable digital I/O terminals • 1x switched 12V OUT; 1x voltage excitation terminals • 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional), Wi-Fi (optional) • 30MB serial flash memory • Integral surge and ESD protection • Integrated 12 V battery solar charge regulator to charge batteries • Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols • Standard operating range of data logger -40° … +70°C • Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 6x single-ended or 3x differential freely programmable analog or digital IN & OUT • 8x pulse counting terminals with 2x control terminals • 7x configurable digital I/O terminals • 2x switched 12V OUT; 2x voltage excitation terminals • 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional) • 30MB serial flash memory • Integral surge and ESD protection • Integrated 12 V battery solar charge regulator to charge batteries • Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols • Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 4x multi-purpose analog input terminals: analog functions, digital I/O functions • 2x pulse counting programmable terminals • 2x configurable control digital I/O terminals • 2x switched 12V OUT; 2x voltage excitation terminals • 1x RS232, 1x RS-485, 1x USB Type C 2.0 • 50MB serial flash memory • Integral surge and ESD protection • Integrated 12 V battery solar charge regulator to charge batteries • Connect with PakBus, Modbus, DNP3, SDI-12, and other standard communication protocols • Standard operating range of data logger -40° … +70°C
• An all-digital measurement and control DAQ • 24-bit ADC • 12x individually configured inputs for analog or digital functions • 16x terminals configurable for digital I/O • Built-in Wi-Fi and USB Micro-B for computer connectivity • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• One of the most computationally powerful data-acquisition devices from Campbell Scientific • 24 bit and 32 bit ADC • An all-digital measurement and control DAQ • 8x digital I/O terminals (configurable) • 2x switched 12V • EPI port switch for high-speed connection to all GRANITE modules • Built-in GPS for network synchronization • Built-in Wi-Fi • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• One of the most computationally powerful data-acquisition devices from Campbell Scientific • 24 bit and 32 bit ADC • An all-digital measurement and control DAQ • 8x digital I/O terminals (configurable) • 4 General-purpose CAN channels • 2x switched 12V • EPI port switch for high-speed connection to all GRANITE modules • Built-in GPS for network synchronization • Built-in Wi-Fi • 4 Mbytes battery-backed SRAM + 128 MB NOR flash memory, expandable to 16 GB • Onboard storage of streaming data with 2 GB of DDR3 SDRAM and 64 GB SSD • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Compliant to recommendations of FGW TR6, IEC and MEASNET • Incl. calibration certificate • Calibration standards traceable to ilac-MRA accreditation service
• Compliant to recommendations of FGW TR6, IEC and MEASNET • Incl. calibration certificate • Calibration standards traceable to ilac-MRA accreditation services
• Compliant to recommendations of FGW TR6, IEC and MEASNET • Incl. calibration certificate • Calibration standards traceable to U.K.A.S accreditation service
• 16x analogue single-ended or 8 differential IN • 2x digital pulse counters IN • 8x digital IN/OUT • 3x analogue voltage OUT • 1x switched 12V OUT • RS232 • CS I/O PORT, SDI-12, Peripheral ports • CF-card, USB, LAN, WLAN (optional) • 2/4 Mbytes SRAM memory • Surge protection for all Inputs by gas discharge tube (GDT) • Surge protection for critical outputs by GDT or transient voltage suppression diodes • Power feeding protected by transzorb diodes • Grounding socket for electrostatic discharge (ESD) protection
• Once powered up, the measurement automatically starts • Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available • 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT • RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available • 2/4 Mbytes SRAM memory (optionally extendable) • Surge protection for all Inputs by gas discharge tube (GDT)
• Once powered up, the measurement automatically starts • 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT • RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available • 2/4 Mbytes SRAM memory (optionally extendable) • Keypad and LCD Display • Surge protection for all Inputs by gas discharge tube (GDT) • Standard operating range of data logger -25° … +50°C (optionally extended: -30° … +80°C)
• Compatible with PV1000X and other models • Connects to the data logger via three ports that can be shared with up to 15 other SDM devices • Adds 16 digital I/O ports • Operating Temperature: -40°C to 70°C
• Increases the number of sensors the data logger can measure • Allows to multiplex up to 64 sensors • Decreases cost of cabling individual sensors • Electrical surge protection • Operating voltage: 9-16 VDC • Operating temperature: -25°C to 50°C (standard), -55°C to 85°C (extended)
• Keypad with display for easy access • Compatible with PV1000X • Allows to check Datalogger status, change ports, enter numeric data and view or plot sensor data • Operating temperature: -45°C to 85°C
• Compact Flash Module • For CR1000 and CR3000 • Expands data logger storage via CompactFlash® by up to 2 GB • Connects directly to the peripheral port
• Ethernet Interface • Allows communications over local networks via TCP/IP • Compact Flash Module • Expands data logger storage via CompactFlash® by up to 2 GB • For CR1000 and CR3000 • Connects directly to the peripheral port
• USB (2.0) interface with up to 2GB flash storage • Allows Plug&Play field upgrades and configuration by using our Device Configuration utility • Expands data logger storage by 2 GB, tandem operation with Compact Flash card possible • Shuttles data, OS, and program files between Campbell Scientific dataloggers and a PC • For CR800, CR850, CR1000, CR6, CR3000, CR5000, CR9000(X)
• General-purpose, multiplexed analog measurement module • 8 differential or 16 single-ended input channels with 2 excitation channels • 1x switched 12V and 2x switched 5V • Channel count expansion via the CPI bus • USB 2.0 interface for direct-to-PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• General-purpose, multiplexed analog measurement module • 16 differential or 32 single-ended input channels with 2 excitation channels • 2x switched 12V and 4x switched 5V • Channel count expansion via the CPI bus • USB 2.0 interface for direct-to-PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Purpose-built thermocouple measurement module • Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers • 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors • Resolution of 0.015°C • Handles extreme temperature environments and rapid thermal gradients • Time base can be referenced either to GPS or a temperature-compensated real-time clock • CPI DAQ connection for channel expansion • USB 2.0 interface for PC-based operation • Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)
• Purpose-built photovoltaic resource data platform • Ideal for distributed PV monitoring and functioning as a plane-of-array (POA), albedo, and soiling secondary weather station • Intuitive onboard user interface accessed by a web browser • SCADA ready with Modbus RTU and Modbus TCP/IP • Internal Memory: 3 months' storage of 1- and 10-min average
• 8 lines x 21 characters with 16-character keyboard • Powered by the data logger power supply • Allows to check the datalogger's status, display or plot sensor readings and stored values, and enter numeric data or change port/flag state • Supports custom menus • Can be easily carried from station to station in a datalogger network
• CURS100 • Enables a Campbell Scientific data logger to measure a sensor with current output signal, e.g. 4-20 mA; converts the current signal to voltage signal
• 4WPB100 • Provides completion resistors to measure 100-Ohm platinum resistive thermometer (PRT) using the half-bridge four-wire measurement method on a Campbell Scientific data logger
• 4WPB1K • Provides completion resistors to measure 1000-Ohm platinum resistive thermometer (PRT) using the half-bridge four-wire measurement method on a Campbell Scientific data logger
• Ammonit Meteo-42A • With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others • 14x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit) • 2x pulse counter IN • 4x digital serial status IN • 1 RS485 Client IN (for up to 2 smart sensors or Ultra Sonic Anemometers) • 4x analog voltage OUT (5V | Switches) • 1x analog current OUT • 1 RS485 Server OUT (SCADA monitoring software) • 3 USB (2x USB-A host, 1x USB-B device) • 1 LAN (Ethernet)
• Ammonit Meteo-42M • With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others • 8x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit) • 8x pulse counter IN • 4x digital serial status IN • 1 RS485 Client IN (for up to 2 smart sensors or Ultra Sonic Anemometers) • 4x analog voltage OUT (5V | Switches) • 1x analog current OUT • 1 RS485 Server OUT (SCADA monitoring software) • 3 USB (2x USB-A host, 1x USB-B device) • 1 LAN (Ethernet)
• Ammonit Meteo-42L • With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others • 14x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit) • 12x pulse counter IN • 7x digital serial status IN • 1 RS485 Client IN (for up to 3 smart sensors or Ultra Sonic Anemometers) • 8x analog voltage OUT (5V | Switches) • 1x analog current OUT • 1 RS485 Server OUT (SCADA monitoring software) • 3 USB (2x USB-A host, 1x USB-B device) • 1 LAN (Ethernet)
• Ammonit Meteo-40S Plus • With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others • 4x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit) • 1x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit) • 4x pulse counter IN • 2x digital serial status IN • 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers) • 2x analog voltage OUT (5V | Switches) • 1x analog current OUT • 1 RS485 Slave OUT (SCADA monitoring software) • 3 USB (2x USB-A host, 1x USB-B device) • 1 LAN (Ethernet)
• Ammonit Meteo-40M Plus • With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others • 8x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit) • 1x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit) • 8x pulse counter IN • 4x digital serial status IN • 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers) • 4x analog voltage OUT (5V | Switches) • 1x analog current OUT • 1 RS485 Slave OUT (SCADA monitoring software) • 3 USB (2x USB-A host, 1x USB-B device) • 1 LAN (Ethernet)
• Ammonit Meteo-40L Plus • With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others • 12x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit) • 2x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit) • 12x pulse counter IN • 8x digital serial status IN • 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers) • 8x analog voltage OUT (5V | Switches) • 2x analog current OUT • 1 RS485 Slave OUT (SCADA monitoring software) • 3 USB (2x USB-A host, 1x USB-B device) • 1 LAN (Ethernet)
• Compliant to recommendations of FGW TR6, IEC and MEASNET • Incl. calibration certificate • Calibration standards traceable to DAkkS (ilac-MRA) accreditation service
• M83575 • 3 Ports: Pull-Up 5.1kOhm, Compact Vane • 3 Ports: First Class Vane etc., 10mA • 2 Ports: Pull-Down 10kOhm • 2 Ports: Configurable, open • RS485: Resistors for Biasing and Termination • Output: 5V/100mA • Supply: 9 to 32VDC
• M83570 • 10 individually configurable ports: Current limit 10 mA, Pull-up resistor 5.1 kOhm with current limit 1 mA, and Pull-down resistor 10 kOhm • 2-wire RS485: Biasing and Bus-termination terminal • 1x stabilized and ripple-free 5 V output with 110 mA current limit • Supply: 9 to 32VDC
• M83200 • Converts AC signal inputs into pulse outputs • Provides stabilized and ripple-free 5 V output with 110 mA current limit • Supply: 9 to 32VDC
• Orbit 360 Premium Data Logger • 16x frequency channels [pulse counter](10 physical + 6 extra channels with Channel Expander) • 23x analog channels [voltage] (15 physical + 8 extra channels with Channel Expander) • 3x RS485 Client, 1x RS485 Server • 2G/3G/4G Modem • External Power Supply: 5-30 VDC, Internal Backup Battery 17.000 mAh • High capacity backup memory • Secure GPS encrypted • Communication with SCADA • Sampling Rate: 1Hz
• Orbit 360 Basic Data Logger • 10x Frequency channels (pulse counter) • 15x Analog channels (voltage) • 2G/3G/4G Modem • High capacity backup memory • External Power Supply: 5-30 VDC, Internal Backup Battery 17.000 mAh • Secure GPS encrypted • Sampling Rate: 1Hz
• Compatible with Orbit 360 Premium Data Logger • Adds 6 more frequency channels to the Orbit 360 Premium • Each channel can be configured individually • Excellent noise and interface protectionT • Resolution: 16 bits • IEC-61400.12.1 approved sampling rate of 1Hz
• Compatible with Orbit 360 Premium Data Logger • Easy maintenance, prevents mis-wiring • Increased protection against electrostatic discharges • Channel capacity: All Orbit 350 Channels (25) + Modbus RTU + RS485 Buses (3) + Ext. Com • Insterted directly into the Orbit 360 terminal plugs
• Compatible with Orbit 360 Basic Data Logger • Easy maintenance, prevents mis-wiring • Increased protection against electrostatic discharges • Channel capacity: All Orbit 350 Channels (25) + Modbus RTU + RS485 Buses (3) + Ext. Com • Insterted directly into the Orbit 360 terminal plugs
• Collects and processes sensor measurement data using advanced algorithms • Stores observations, device information and maintenance history • Operating conditions: -40°C... +85°C, 0 ... 100 %RH • Operating voltage: 8-32V DC (max. 10A)
• 12x pulse counters IN • 7x analog voltage IN • Requires external 12VDC power supply • 7x configurable 'Flex' Channels (Analog or Counter) with optional signal conditioning modules (P-SCMs) • 512 MB SD Card, non-volatile flash memory • Resolution: 16 bit ad • Accuracy: 0.04 % of full scale • LCD with 16 button keypad • 2x RS485 serial communication on wiring panel
• 8x pulse counters IN • 3x analog voltage IN • Requires external 12VDC power supply • 3x configurable 'Flex' Channels (Analog or Counter) with optional signal conditioning modules (P-SCMs) • Resolution: 16 bit ad • Accuracy: 0.04 % of full scale • LCD with 16 button keypad
{{.}}
{{{.}}}