• 4.3820.00.000 • Measurement variables possible (2 dimensions): • Horizontal components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° (0...540°, 0...720° analogue adjustable) • Virtual temperature measurement range: - 50°C ... +70°C • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Maintenance free • Digital /analogue in- and outputs
• 4.3820.32.503 • Measurement variables possible (2 dimensions): • Horizontal components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° (0...540°, 0...720° analogue adjustable) • Virtual temperature measurement range: - 50°C ... +70°C • Half Duplex Interface Configuration with Baud rate of 38400/N81 • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Maintenance free
• 4.3820.42.503 • PTC Heating Stainless-steel caps and additional chassis heating • Measurement variables possible (2 dimensions): • Horizontal components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° (0...540°, 0...720° analogue adjustable) • Virtual temperature measurement range: - 50°C ... +70°C • Half Duplex Interface Configuration with Baud rate of 38400/N81 • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 48V AC/DC • Maintenance free
• 4.3875.00.260 • Standard Heating Stainless-steel caps • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Interface Configuration with Baud rate of 4800/N81 and NMEA Telegram • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3875.00.340 • Standard Heating Stainless-steel caps • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3875.20.381 • Standard Heating Stainless-steel caps • With optionally integrated Baro-transmitter • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3877.07.000 • Standard Heating Stainless-steel caps • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3877.27.000 • Standard Heating Stainless-steel caps • With optionally integrated Baro-transmitter • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3875.20.340 • Standard Heating Stainless-steel caps • With optionally integrated Baro-transmitter • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 12 VDC • Maintenance free
• 4.3875.60.340 • Reinforced heating with 48 VDC • Measurement variables possible (2 dimensions): orthogonal wind velocity vectors (X- and Y-distance), scalar / vectorial wind velocity wind direction, and acoustic-virtual temperature • Wind measurement range: [0.01 ... 75 m/s] • Wind direction measurement range: 0 ... 360° • Virtual temperature measurement range: - 50°C ... +70°C • Full Duplex Configuration with Baudrate 9600/N81 and VDT-Telegram (Telegram2) • Output range: 10 per 1 sec • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics 12 VDC • Maintenance free
• For 2D and 3D ultra sonic anemometer • Wind speed: at 1 azimuth position (by default at 0°), with 13 points at 13 wind speeds • Wind direction: over 380° (350° ... 10°) at 8 m/s • MEASNET wind tunnel calibration • Traceable according to DAkkS (ilac-MRA)
• For 2D and 3D ultra sonic anemometer • Wind speed: at 2 azimuth positions (by default at 0° and 180°), each with 13 points at 13 wind speeds • Wind direction: over 380° (350° ... 10°) at 8 m/s • MEASNET wind tunnel calibration • Traceable according to DAkkS (ilac-MRA)
• 4.3830.20.340 • Measurement variables possible (3 dimensions): • Horizontal and vertical components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 85 m/s] • Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90° • Virtual temperature measurement range: - 40°C ... +70°C • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Maintenance free • Digital /analogue in- and outputs
• 4.3830.22.503 • Measurement variables possible (3 dimensions): • Horizontal and vertical components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 85 m/s] • Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90° • Virtual temperature measurement range: - 40°C ... +70°C • Sample rate: 0.1 Hz ... 100 Hz • Half Duplex Interface Configuration with Baud rate of 38400/N81 • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Maintenance free
• 4.3830.42.503 • PTC Heating Stainless-steel caps and additional chassis heating • Measurement variables possible (3 dimensions): • Horizontal and vertical components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0.01 ... 85 m/s] • Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90° • Virtual temperature measurement range: - 40°C ... +70°C • Sample rate: 0.1 Hz ... 100 Hz • Half Duplex Interface Configuration with Baud rate of 38400/N81 • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Supply of electronics and heating of 48V AC/DC • Maintenance free
For 3 tilt angles: • Wind speed: at 1 azimuth position (by default at 0°), with 13 points at 13 wind speeds • Wind direction: over 380° (350° ... 10°) • MEASNET wind tunnel calibration • Traceable according to DAkkS (ilac-MRA)
• 1590-PK-020/W • Wind speed measurement range: 0 ... 50 m/s • Wind direction measurement range: 0 ... 360° • Digital output: RS232, 422, 485, Binary, Baudrate 2400-57600, ASCII • 4 channels available as analog outputs: 0-20mA, 4-20mA, 0-5 V, ±2.5 V, ±5 V, resolution 12 or 14 bits • Operating temperature range: -40°C to 70°C • Power requirement: 9-30 VDC
• 507245 • Consisting of 1x wire and 2x clip • Suitable for Thies Ultrasonic Anemometer 1D and 2D
• 508396 • Consisting of 1x spike and protective cap • Suitable for Thies Ultrasonic Anemometer 1D, 2D, and 3D
• 4.3865.01.310 • Measurement variables possible (1 dimension): • Horizontal components of wind speed • Wind direction • Virtual temperature • Wind measurement range: [0 ... 75 m/s] • Wind direction measurement range: 0° (1°) / 180° (181°) and "calm" • Virtual temperature measurement range: - 50°C ... +70°C • Sample rate: 0.1 Hz ... 100 Hz • Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated) • Maintenance free • Digital /analogue in- and outputs
• Adapter is aligned to north by means of a bearing tube • A pin in the adapter and a north boring in the base of the anemometer guarantee that the sensor is aligned to north • No realignment necessary with replacement of the sensor • Fixing boring for mast and sensor of 50mm diameter • Aluminum
• Wind speed: in 1 azimuth position with 13 points at 13 wind speeds • MEASNET wind tunnel calibration • Traceable according to DAkkS (ilac-MRA)
• Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
• LiYCY (TP) BK • Manufactured with special PVC-based compound insulation and cores twisted to pairs • Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
For Thies Ultrasonic Anemometers: • Inspection and Checkup • Verification of measurements and configuration • Inspection report • Certificate
{{.}}
{{{.}}}