• 5.4106.00.100 • Precipitation (yes/no) • 18 cm2 sensor area • Semiconductor relay, Potential-free / electrically isolated / metallically separated • Sensitivity: approx. 0.2 mm/h • Operating voltage: 11...28VAC or 11...32VDC (max. 0.75A)
• 5.4103.10.700 • Precipitation (rain, snow, hail, etc.) • 25 cm2 sensor area • Signal output: Precipitation = relay OFF; no precipitation = relay ON • Operating voltage: 24V AC/DC
• Typical range of operation: 0.0 .. 1.8mm/minute rainfall intensity (normal rainfall intensity is in the range 0.1 ... 0.5 mm/minute) • Accuracy: +/-2% • Resolution: 0.20mm per “tip” (0.10mm, 0.25 and 0.50mm also available) • Incl. individual calibration certificate
• Accuracy: ±10% • Resolution: 0.01in/0.2mm Alternative 0.001in/0.02mm • Input Voltage: 5-35 VDC • Output: NPN Collector Output 500mA / 80V / 300mW Max • Free of maintenance
• WMO8 Compliant • Typical range of operation: 0.0 .. 1.8mm/minute rainfall intensity (normal rainfall intensity is in the range 0.1 .. 0.5 mm/minute) • Accuracy: +/-2% • Incl. individual calibration certificate • Heated version or Stainless Steel version available optionally on request
• Unheated, operating temperature: ≥0°C ... +50°C • Meets the specifications of the World Meteorological Organization (WMO) • Durable and corrosion resistant • Factory calibrated
• Heated, operating temperature: -20°C ... +50°C • Meets the specifications of the World Meteorological Organization (WMO) • Durable and corrosion resistant • Factory calibrated • 120V/60HZ or 220V/50-60HZ (H model)
• Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
• LiYCY (TP) BK • Manufactured with special PVC-based compound insulation and cores twisted to pairs • Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
{{.}}
{{{.}}}