Suche
• W200P/FC • Potentiometer 0 … 10 kOhm ±15% = 0 … 360 degrees • Measurement range: 1.15°...358.85° • Dead band: 2.3° ±1.5º (continuity; north gap) / 3.5° ±1.5º (variation; dead band) • Accuracy: ± 3º in steady winds > 3.5m/s (±2° obtainable following calibration) • Resolution: better than 0.2° • Survival speed: ≥ 80m/s (160 knots, 180mph) • Temperature range: -40 to +70ºC
• W200P • Potentiometer 0 … 1 kOhm ±10% = 0 … 360 degrees • Measurement range: 1.15°...358.85° • Dead band: 2.3° ±1.5º (continuity; north gap) / 3.5° ±1.5º (variation; dead band) • Accuracy: ± 3° in steady winds >5m/s (±2° obtainable following calibration) • Resolution: ± 0.2° • Survival speed: 75m/s (150Knots, 170mph) • Temperature range: -50 to +70°C
• W200P/L • Potentiometer 0 … 2 kOhm ±10% = 0 … 360 degrees • Low-torque 2K Ohm potentiometer, more responsive to light winds • Measurement range: 1.15°...358.85° • Dead band: 3° ±2º (continuity; north gap) / 5° ±3º (variation; dead band) • Accuracy: ± 4° in steady winds >3m/s • Resolution: ± 0.25° • Survival speed: 75m/s (150Knots, 170mph) • Temperature range: -30 to +70°C
• A100R/K • Switching anemometer (reed switch) • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100LM • Low power pulse output (10 Hz per m/s) • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100LM/PC3 • Low power pulse output (10 Hz per m/s) • Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike. • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100LK • Low power pulse output (10 Hz per knot) • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100LK/PC3 • Low power pulse output (10 Hz per knot) • Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike. • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100L2 • Low power pulse frequency • Analogue Voltage output • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100L2/PC3 • Low power pulse frequency • Analogue Voltage output • Anti-surge option: protects the electronics in the device against any surges voltages/currents induced in the instrument cable by a nearby lightning strike. • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
• A100AC • Low power • Low level AC output (1.55 Hz per m/s) • First Class in accordance to IEC 61400-12-1 Ed.1 and 61400-12-1 Ed.2
{{.}}
{{{.}}}