ClimaVUE50 Compact Digital Weather Sensor
• Affordable all-in-one meteorological sensor
• Uses SDI-12 to report air temperature, relative humidity, vapor pressure, barometric pressure, wind (speed, gust, and direction), solar radiation, precipitation, and lightning strike
• Less than 1 mA at 12 Vdc average current, making it ideal for solar-powered sites
• Low maintenance—no moving parts significantly reduces maintenance cost and time
• No sensor configuration required
• Integrated tilt sensor helps assure that the sensor stays level over time
• Compact design for quick, low-impact installation
• Compatible with all modern Campbell Scientific data loggers
• Detachable cable facilitates field replacement
• Air temperature: -50°C to +60°C, resolution: 0.1°C, accuracy: ±0.6°C
• Relative humidity: 0 to 100%, resolution: 0.1, accuracy: ±3% RH typical
• Barometric Pressure: 500 to 1100 hPa, resolution: 0.1 hPa, accuracy: ±1 mb (-10°C to +50°C), ±5 mb (-40°C to +60°C)
• Vapor Pressure: 0 to 47 kPa, resolution: 0.1 kPa, accuracy: varies with temperature and humidity; ±0.2 kPa typical below 40°C
• Wind speed: 0 to 30 m/s, resolution: 0.01 m/s, accuracy: 0.3 m/s or 3%
• Wind direction: 0 to 359°, resolution: 1°, accuracy: ±5°
• Solar Radiation: 0 to 1750 W/m2, resolution: 1 W/m2, accuracy: ±5% of measurement
• Precipitation: 0 to 400 mm/h, resolution: 0.017 mm, accuracy: ±5% of measurement
• Tilt: -90° to +90°, resolution: 0.1°, accuracy: ±1°
• Lightning Strike Count: 0 to 65,535 strikes, resolution: 1 strike, accuracy: > 25% detection at < 10 km typical (variable with distance)
• Lightning Average Distance: 0 to 40 km, resolution: 3 km, accuracy: variable
• Operating Temperature Range: -50°C to +60°C (Barometer and RH: -40°C to +60°C)
• Supply Voltage: 3.6 VDC to 15 VDC continuous
• Typical Current Drain @12VDC: < 1mA (average)
• Maximum Peak Current: 33mA
• Connection: 25mm pigtail with M12 male 5-pin 316 stainless-steel knurl
• Dimensions: 10cm diameter, 34cm height, 839.15 g weight