Hukseflux SR05-D1A3Pyranometer (calibrated)
• ISO 9060: Class C
• Measurement range: 0 to 2000 W/m²
• Spectral range: 285 to 3000 nm
• Incl. calibration sheet with each sensor; traceable to World Radiometric Reference (WRR)
• Zero offset (response to 200 W/m² net thermal radiation): < ± 15 W/m²
• Response time: 18 s
• Non-linearity (100 to 1000 W/m2): < ± 1 %
• Directional response: < ± 25 W/m2
• Temperature response: < ± 3 % (-10 to +40 °C)
• Tilt response: < ± 2 % (0 to 90 ° at 1000 W/m2)
• Rated operating temperature range: -40 to +80 °C
• IP 67
• Communication:
Analog: 0 to 1 V
Digital: Modbus RS-485
Datenblatt