Search
Current filter
• 650...1050 hPa • Calibrated with traceable calibration certificate and mark (ilac-MRA) • Output signal: 0...5V DC • Supply Voltage: 8 ... 32 V • Operating temperature: -40 ... 105°C
• 800...1050 hPa • Calibrated with traceable calibration certificate and mark (ilac-MRA) • Output signal: 0...5V DC • Supply Voltage: 8 ... 32 V • Operating temperature: -40 ... 105°C
• 3.1157.10.000 • 0...5V output, set 800...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.040 • 0...20mA output, set 600...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.041 • 4...20mA output, set 600...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.141 • 4...20mA output, set 800...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 3.1157.10.140 • 0...20mA output, set 800...1060 hPa • 300...1100 hPa scalable • Long-term stability ±0.3 hPa/year • Accuracy ±1.0 hPa (unheated) • Accuracy ±0.25 hPa (heated)
• 500...1100 hPa • Long-term stability ±0.1 hPa/year • Accuracy ±0.3 hPa at +20 °C • Traceable NIST calibration incl. certificate
• 500 ... 1100 hPa or 50 .... 1100 hPa pressure ranges with serial output • Different scalings between 500 ... 1100 hPa with analog output • Long-term stability ±0.1 hPa/year • Accuracy ±0.15 hPa at +20 °C • Traceable NIST calibration incl. certificate
• 500 ... 1100 hPa • Long-term stability ±0.1 hPa/year • Accuracy ±0.10 hPa at +20 °C • Traceable NIST calibration incl. certificate
• 500 ... 1100 hPa (optional range settings) • Long-term stability ±0.1 hPa/year • Accuracy ±0.15 hPa at +20 °C • Traceable NIST calibration incl. certificate
• BaroVUE10 • 500 ... 1100 hPa • Long-term stability ±0.1 hPa/year • Calibration Uncertainty ±0.15 hPa • Resolution 0.1 hPa
• K611PB • 600...1100 hPa • Frequency range: 1 - 500 Hz • Supply voltage: 3.3 - 30V • Accuracy ±0.52 hPa at +20 °C • Low energy consumption/Input current (1.8mA)
• 800...1100 hPa • Accuracy (-10 ... 60 °C): ±1% of Full Scale Output (~3 hPa) • Operating environmental conditions: 0 ... 98% relative humidity • Long-term stability ±0.1% of Full Scale Output/year (~0.3hPa)
• 600...1100 hPa • Accuracy (-10 ... 60 °C): ±1% of Full Scale Output (~5 hPa) • Operating environmental conditions: 0 ... 98% relative humidity • Long-term stability ±0.1% of Full Scale Output/year (~0.5hPa)
• ilac-MRA accredited calibration • DAkkS accredited calibration • Compliant to recommendations of FGW TR6, IEC and MEASNET • Incl. calibration certificate
• Measurement range T: -40... +85°C • Measurement range rH: 0...100 %rH • Measurement range P: 300...1200 hPa • Electrical output: 0...1V; 0...10V; 4...20mA • Serial output: RS485, Half-duplex 8N1 (Baud rate configurable)
• ISO conform calibration by accredited Calibration Laboratory • Compliant to recommendations of FGW TR6, IEC and MEASNET • Incl. calibration certificate
• Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
• LiYCY (TP) BK • Manufactured with special PVC-based compound insulation and cores twisted to pairs • Includes mounting of sensor-specific connectors / plugs / jacks • Sensor-specific wiring scheme included • Line-to-line calibration according to IEC, MEASNET and FGW recommendations • Labelling provided for easy plug&play installation on site
{{.}}
{{{.}}}