Datenlogger

Datenlogger
Ammonit Meteo-40S Plus

​Ammonit Meteo-40S Plus
• With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others
• 4x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit)
• 1x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit)
• 4x pulse counter IN
• 2x digital serial status IN
• 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers)
• 2x analog voltage OUT (5V | Switches)
• 1x analog current OUT 
• 1 RS485 Slave OUT (SCADA monitoring software)
• 3 USB (2x USB-A host, 1x USB-B device)
• 1 LAN (Ethernet)

2.095,00 EUR
 
Meteo-40S Plus Data Logger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET

• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to DAkkS (ilac-MRA) accreditation service

200,00 EUR
 
Ammonit Meteo-40M Plus

​Ammonit Meteo-40M Plus
• With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others
• 8x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit)
• 1x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit)
• 8x pulse counter IN
• 4x digital serial status IN
• 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers)
• 4x analog voltage OUT (5V | Switches)
• 1x analog current OUT 
• 1 RS485 Slave OUT (SCADA monitoring software)
• 3 USB (2x USB-A host, 1x USB-B device)
• 1 LAN (Ethernet)

2.460,00 EUR
 
Meteo-40M Plus Data Logger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET

• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to DAkkS (ilac-MRA) accreditation service

250,00 EUR
 
Ammonit Meteo-40L Plus

​Ammonit Meteo-40L Plus
• With new firmware version offering flexibility in the user setttings, sensor and modem configuration, data security, among others
• 12x analog voltage IN (± 0.1V, ± 1V, ± 10V 16bit)
• 2x analog current IN (± 1mA, ± 10mA, ± 100mA 16bit)
• 12x pulse counter IN
• 8x digital serial status IN
• 1 RS485 Master IN (for up to 8 smart sensors or Ultra Sonic Anemometers)
• 8x analog voltage OUT (5V | Switches)
• 2x analog current OUT 
• 1 RS485 Slave OUT (SCADA monitoring software)
• 3 USB (2x USB-A host, 1x USB-B device)
• 1 LAN (Ethernet)

2.985,00 EUR
 
Meteo-40L Plus Data Logger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET

• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to DAkkS (ilac-MRA) accreditation service

300,00 EUR
 
Isolated RS-485 Repeater for Thies Ultrasonic Anemometer to Meteo-40 Connection

M83575
• 3 Ports: Pull-Up 5.1kOhm, Compact Vane
• 3 Ports: First Class Vane etc., 10mA
• 2 Ports: Pull-Down 10kOhm

• 2 Ports: Configurable, open
• RS485: Resistors for Biasing and Termination
• Output: 5V/100mA
• Supply: 9 to 32VDC

290,00 EUR
 
Ammonit Module for 10 Ports, RS-485, and 5V Output

M83570
• 10 individually configurable ports: Current limit 10 mA, Pull-up resistor 5.1 kOhm with current limit 1 mA, and Pull-down resistor 10 kOhm
• 2-wire RS485: Biasing and Bus-termination terminal 
• 1x stabilized and ripple-free 5 V output with 110 mA current limit

• Supply: 9 to 32VDC

175,00 EUR
 
Ammonit Module for AC Converter and 5 V Output

M83200
• Converts AC signal inputs into pulse outputs
• Provides stabilized and ripple-free 5 V output with 110 mA current limit

• Supply: 9 to 32VDC

95,00 EUR
 
Campbell Scientific CR1000X Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 16x analogue single-ended or 8 differential Analog Inputs, 10x pulse counters, 8x digital IN/OUT (configurable), 4x analogue voltage (switched excitation mode or switched regulated voltage supply), 2x switched 12V 
• RS232, CS I/O PORT to CSI peripherals, USB, Ethernet (LAN) port, Wi-Fi (optional module)
• 4 Mbytes battery-backed SRAM + 72 MB flash memory, expandable to 8 GB
• Surge, Electrostatic Discharge and Lightning Protection for all critical Inputs and Outputs
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
 
CR1000X Data Logger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET

• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to ilac-MRA accreditation service

360,00 EUR
 
Campbell Scientific CR1000 - Data Logger embedded in our measurement systems

• 16x analogue single-ended or 8 differential IN
• 2x digital pulse counters IN
• 8x digital IN/OUT
• 3x analogue voltage OUT
• 1x switched 12V OUT
• RS232
• CS I/O PORT, SDI-12, Peripheral ports
• CF-card, USB, LAN, WLAN (optional)
• 2/4 Mbytes SRAM memory
• Surge protection for all Inputs by gas discharge tube (GDT)
• Surge protection for critical outputs by GDT or transient voltage suppression diodes
• Power feeding protected by transzorb diodes
• Grounding socket for electrostatic discharge (ESD) protection

Preis auf Anfrage
 
CR1000 Data Logger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET

• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to ilac-MRA accreditation services

360,00 EUR
 
Campbell Scientific CR6 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 12x single-ended or 6x differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN, USB, RJ-45, Micro-SD card 
• 4 Mbytes SRAM memory (extendable)
• Surge protection for critical Outputs by GDT or transient voltage suppression diodes
• Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)

Preis auf Anfrage
 
Campbell Scientific CR6-WIFI Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 12x single-ended or 6x differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN, USB, RJ-45, Micro-SD card 

• WLAN Wi-Fi for short-range wireless IP communications based on 802.11 b/g/n, WPA/WPA2-Personal, WPA/WPA2-Enterprise Security, WEP
• 4 Mbytes SRAM memory (extendable)
• Surge protection for critical Outputs by GDT or transient voltage suppression diodes
• Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)

Preis auf Anfrage
 
CR6 (-RF422 / -WIFI) Data Logger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET

• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to ilac-MRA accreditation service

360,00 EUR
 
Campbell Scientific CR6-RF4XX Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service)
• 12x single-ended or 6x differential freely programmable analog or digital IN & OUT
• 4x digital pulse counters IN an/or 4x analog voltage OUT (5 and 3.3V)
• 2x switched 12V OUT
• 1x RS232 / RS485
• CS I/O PORT
• LAN, USB, RJ-45, Micro-SD card 

• Internal RF422 modem (or optional for specific countries: RF407, RF412, RF451)
• 4 Mbytes SRAM memory (extendable)
• Surge protection for critical Outputs by GDT or transient voltage suppression diodes
• Standard operating range of data logger -40° … +70°C (optionally extended: -55° … +85°C)

Preis auf Anfrage
 
Campbell Scientific CR300 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available
• 6x single-ended or 3x differential freely programmable analog or digital IN & OUT
• 8x pulse counting terminals with 2x control terminals
• 7x configurable digital I/O terminals
• 1x switched 12V OUT; 1x voltage excitation terminals

• 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional), Wi-Fi (optional)
• 30MB serial flash memory
• Integral surge and ESD protection
• Integrated 12 V battery solar charge regulator to charge batteries
• Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols
• Standard operating range of data logger -40° … +70°C
• Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications

Preis auf Anfrage
 
Campbell Scientific CR310 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available
• 6x single-ended or 3x differential freely programmable analog or digital IN & OUT
• 8x pulse counting terminals with 2x control terminals
• 7x configurable digital I/O terminals
• 2x switched 12V OUT; 2x voltage excitation terminals

• 1x RS232, 1x USB Micro B, 1x 10/100 Ethernet RJ45 (optional)
• 30MB serial flash memory
• Integral surge and ESD protection
• Integrated 12 V battery solar charge regulator to charge batteries
• Connect with PakBus, Modbus, DNP3, GOES, and other standard communication protocols
• Available in multiple radio, cellular network modem and Wi-Fi options that are suitable for different regions and applications

Preis auf Anfrage
 
Campbell Scientific CR350 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available
• 4x multi-purpose analog input terminals: analog functions, digital I/O functions
• 2x pulse counting programmable terminals
• 2x configurable control digital I/O terminals
• 2x switched 12V OUT; 2x voltage excitation terminals

• 1x RS232, 1x RS-485, 1x USB Type C 2.0
• 50MB serial flash memory
• Integral surge and ESD protection
• Integrated 12 V battery solar charge regulator to charge batteries
• Connect with PakBus, Modbus, DNP3, SDI-12, and other standard communication protocols
• Standard operating range of data logger -40° … +70°C

Preis auf Anfrage
 
Campbell Scientific CR800 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• Calibration certificate (standards traceable to U.K.A.S accreditation service) optionally available
• 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT
• RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available
• 2/4 Mbytes SRAM memory (optionally extendable)
• Surge protection for all Inputs by gas discharge tube (GDT)

Preis auf Anfrage
 
CR800 Data Logger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET

• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to ilac-MRA accreditation services

360,00 EUR
 
Campbell Scientific CR850 Data Logger in our Measurement Systems for Renewable Energy Resource Assessments

• Once powered up, the measurement automatically starts
• 6x analog single-ended or 3 differential IN, 2x digital pulse counters IN, 4x digital IN/OUT, 3x analog voltage OUT, 1x switched 12V OUT
• RS232, CS I/O PORT, optionally: USB, Ethernet (LAN), WiFi and CF-card modules available
• 2/4 Mbytes SRAM memory (optionally extendable)
​• Keypad and LCD Display
• Surge protection for all Inputs by gas discharge tube (GDT)
• Standard operating range of data logger -25° … +50°C (optionally extended: -30° … +80°C)

Preis auf Anfrage
 
CR850 Data Logger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET

• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to ilac-MRA accreditation services

360,00 EUR
 
CR3000 Data Logger Calibration - compliant to recommendations of FGW TR6, IEC and MEASNET

• Compliant to recommendations of FGW TR6, IEC and MEASNET
• Incl. calibration certificate
• Calibration standards traceable to U.K.A.S accreditation service

360,00 EUR
 
Campbell Scientific MeteoPV- Monitoring Platform

• Purpose-built photovoltaic resource data platform
• Ideal for distributed PV monitoring and functioning as a plane-of-array (POA), albedo, and soiling secondary weather station
• Intuitive onboard user interface accessed by a web browser
• SCADA ready with Modbus RTU and Modbus TCP/IP
• Internal Memory: 3 months' storage of 1- and 10-min average

Preis auf Anfrage
 
Campbell Scientific CR1000KD Portable Keyboard and Display Screen

• 8 lines x 21 characters with 16-character keyboard
• Powered by the data logger power supply
• Allows to check the datalogger's status, display or plot sensor readings and stored values, and enter numeric data or change port/flag state
• Supports custom menus
• Can be easily carried from station to station in a datalogger network

Preis auf Anfrage
 
Campbell Scientific CURS100 100-Ohm Current Terminal Input Module

CURS100
• Enables a Campbell Scientific data logger to measure a sensor with current output signal, e.g. 4-20 mA; converts the current signal to voltage signal

 

Preis auf Anfrage
 
Campbell Scientific 4WPB100 100-Ohm, Four-Wire PRT Bridge Terminal Input Module

4WPB100
• Provides completion resistors to measure 100-Ohm platinum resistive thermometer (PRT) using the half-bridge four-wire measurement method on a Campbell Scientific data logger

 

Preis auf Anfrage
 
Campbell Scientific 4WPB1K 1-kOhm, Four-Wire PRT Bridge Terminal Input Module

4WPB1K
• Provides completion resistors to measure 1000-Ohm platinum resistive thermometer (PRT) using the half-bridge four-wire measurement method on a Campbell Scientific data logger

 

Preis auf Anfrage
 
Campbell Scientific CFM100 Compact Flash Module

• Compact Flash Module
• For CR1000 and CR3000
• Expands data logger storage via CompactFlash® by up to 2 GB
• Connects directly to the peripheral port

Preis auf Anfrage
 
Campbell Scientific NL116 Ethernet and CF Card Module

• Ethernet Interface
• Allows communications over local networks via TCP/IP

• Compact Flash Module
• Expands data logger storage via CompactFlash® by up to 2 GB

• For CR1000 and CR3000
• Connects directly to the peripheral port

Preis auf Anfrage
 
Campbell Scientific SC115 USB Storge Extension & Portable Configurator

• USB (2.0) interface with up to 2GB flash storage
• Allows Plug&Play field upgrades and configuration by using our Device Configuration utility
• Expands data logger storage by 2 GB, tandem operation with Compact Flash card possible
• Shuttles data, OS, and program files between Campbell Scientific dataloggers and a PC
• For CR800, CR850, CR1000, CR6, CR3000, CR5000, CR9000(X)

Preis auf Anfrage
 
Kintech Orbit 360 Frequency Channel Expander
0,00 EUR
 
zzgl. 19% MwSt.
Campbell Scientific VOLT 108 - general purpose, multiplexed analog measurement module

• General-purpose, multiplexed analog measurement module
• 8 differential or 16 single-ended input channels with 2 excitation channels
• 1x switched 12V and 2x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation

• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
 
Campbell Scientific VOLT 116 - general purpose, multiplexed analog measurement module

• General-purpose, multiplexed analog measurement module
• 16 differential or 32 single-ended input channels with 2 excitation channels
• 2x switched 12V and 4x switched 5V
• Channel count expansion via the CPI bus
• USB 2.0 interface for direct-to-PC-based operation

• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
 
Campbell Scientific TEMP 120

• Purpose-built thermocouple measurement module
• Part of a data-acquisition system such as the GRANITE Datalogger series, CR6 or CR1000X loggers 
• 20 thermocouple inputs using universal copper-copper standard miniature thermocouple connectors
• Resolution of 0.015°C
• Handles extreme temperature environments and rapid thermal gradients
• Time base can be referenced either to GPS or a temperature-compensated real-time clock

• CPI DAQ connection for channel expansion
• USB 2.0 interface for PC-based operation
• Standard operating range of -40° to +70°C (optionally extended: -55° to +85°C)

Preis auf Anfrage
 
Zeige 1 bis 40 (von insgesamt 40 Artikeln)